Determine the number of policers or meters to use (for example TP). A maximum of 32 meters per policy are available.
Only those meters associated with FCs are considered for number of meters. Note that only ‟FCs in use” is considered.
The number obtained is rounded off to next multiple of ‟2” greater than the TQ obtained using this equation.
The user configures the value of TQ using the num-qos-classifiers command.
For more examples and information about resource allocation, see Service ingress QoS policy configuration considerations.