Knowing the number of traffic types to use per ‟FC in use”, apply the following rules for a SAP in an IES or VPRN service enabled with PIM/multicast enabled to determine the number of classification entries per FC in use:
If an FC is in use and is created without explicit meters, use default meter ‟1” for unicast traffic and for multicast traffic. This requires one classification entry in hardware. This assumes default multipoint meter ‟11” is not created by the user.
If an FC is in use and is created without explicit meters, use default meter ‟1” for unicast traffic and default meter ‟11” (assuming meter ‟11” is created by the user), for multicast traffic. This requires two classification entries in hardware.
If an FC is in use and is created with an explicit unicast meter, use that meter for unicast traffic and for multicast traffic. This requires one classification entries in hardware. This assumes default multipoint meter ‟11”” is not created by the user.
If an FC is in use and is created with an explicit unicast meter, use that meter for unicast traffic and use default meter ‟11” (assuming meter ‟11” is created by the user) for multicast traffic. This requires two classification entries in hardware.