The following describes the usage of meters when meter ‟11” in a VPLS service is defined in the policy:
If an FC is created without explicit meters, use the default meter ‟1” for unicast traffic and default meter ‟11” for all other traffic types (such as broadcast, multicast and unknown-unicast).
If an FC is created with an explicit unicast meter, use that meter for unicast traffic and use default meter ‟11” for all other traffic types.
If an FC is created with an explicit unicast meter and explicit broadcast meter, use these meters for unicast and broadcast traffic respectively and use meter ‟11” for all other traffic types.
If an FC is created with an explicit unicast meter and explicit multicast meter, use the unicast meter for unicast traffic and multicast meter for all other kinds of traffic.
If an FC is created with an explicit unicast meter, an explicit broadcast meter, and an explicit multicast meter, use these meters for unicast, broadcast and multicast traffic types respectively. Unknown unicast traffic type will use the explicitly defined multicast meter.
If an FC is created with an explicit unicast meter, an explicit broadcast meter, an explicit unknown-unicast meter, and an explicit multicast meter, use these meters for unicast, broadcast, unknown-unicast and multicast traffic types respectively.