On the CLI, the adapter cards are referred to as MDAs. A port is identified using the format slot/mda/port, where slot identifies the IOM card slot ID (always 1), mda identifies the physical slot in the chassis for the adapter card, and port identifies the physical port on the adapter card; for example, 1/5/1. Adapter cards are configured at the card and port level.
On the fixed platforms, no configuration is required at the adapter card level in order to provision the ports.
On the CLI for the 7705 SAR-A, the slot/mda identifier for the T1/E1 ports is 1/2 and for the Ethernet ports is 1/1. T1/E1 ports are identified as 1/2/1 through 1/2/8 for the variant of the chassis with T1/E1 ports. Ethernet ports for both variants of the 7705 SAR-A are identified as 1/1/1 through 1/1/12.
On the CLI for the 7705 SAR-Ax, the slot/mda identifier for the Ethernet ports is 1/1 and for the GNSS RF port is 1/2.
On the CLI for the 7705 SAR-H, the slot/mda identifier for the Ethernet ports is 1/1. The chassis has two slots for modules (the 4-port T1/E1 and RS-232 Combination module, the GPS Receiver module, and the 4-port SAR-H Fast Ethernet module). On the CLI, the slot/mda identifier for a module installed in the first slot position is 1/2 and for a module installed in the second slot position is 1/3. Ethernet ports are identified as 1/1/1 through 1/1/8. Module ports are identified as 1/2/port-num for modules installed in the first slot position and 1/3/port-num for modules installed in the second slot position.
On the CLI for the 7705 SAR-Hc, the slot/mda identifier for the Ethernet ports is 1/1 and for the RS-232 ports is 1/2. Ethernet ports are identified as 1/1/1 through 1/1/6 and RS-232 ports are identified as 1/2/1 and 1/2/2.
On the CLI for the 7705 SAR-M, the slot/mda identifier for the Ethernet ports is 1/1 and for the T1/E1 ports is 1/2. For those variants of the chassis that have a module slot, the slot/mda identifier for the module is 1/3. The 7705 SAR-M supports the following modules: CWDM OADM module, 2-port 10GigE (Ethernet) module, and 6-port SAR-M Ethernet module. Ethernet ports for all variants of the 7705 SAR-M are identified as 1/1/1 through 1/1/7. T1/E1 ports are identified as 1/2/1 through 1/2/16 for the variants with T1/E1 ports. Module ports are identified as 1/3/port-num for the variants with module slots.
On the CLI for the 7705 SAR-Wx, the slot/mda identifier for the Ethernet ports is 1/1 and for the GPS connector is 1/3. Ethernet ports for the Ethernet-only variant and the Ethernet and PoE+ variant are identified as 1/1/1 through 1/1/5. For the variant supporting Ethernet ports and a GPS connector, the GPS connector is identified as 1/3/1.
On the CLI for the 7705 SAR-X, the slot/mda identifier for the T1/E1 ports is specified as 1/1 and for the Ethernet ports is 1/2 or 1/3. T1/E1 ports are identified as 1/1/1 to 1/1/8. Ethernet ports are identified as 1/2/port-num or 1/3/port-num, where the port number has a value from 1 to 7, depending on how the port is configured.
For the 16-port T1/E1 ASAP Adapter card, 32-port T1/E1 ASAP Adapter card, and 4-port DS3/E3 Adapter card, the channel-group-id identifies the DS1 or E1 channel group; for example, 1/5/1.20. For the 2-port OC3/STM1 Channelized Adapter card, the channel-group-id identifies the DS1, E1, or DS3 channel group. For the 4-port OC3/STM1 / 1-port OC12/STM4 Adapter card, the channel-group-id identifies the DS1 or E1 channel group. For the 12-port Serial Data Interface card, the channel-group-id identifies the V.35, RS-530, RS-232, or X.21 channel group; only one channel group per port is supported on the card, so the format would be 1/1/1.1.
For the 6-port E&M Adapter card, the channel-group-id identifies the E&M voice channel group; only one channel group per port is supported on the card, so the format would be 1/1/1.1. For the 8-port Voice & Teleprotection card, the 8-port C37.94 Teleprotection card, the 8-port FXO Adapter card, and the 6-port FXS Adapter card, the channel-group-id identifies the DS0 channel group; only one channel group per port is supported on the card, so the format would be 1/1/1.1.
For the 4-port T1/E1 and RS-232 Combination module, the channel-group-id identifies the DS1 or E1 channel group for the T1/E1 ports (for example, 1/2/3.5) or the channel group for the RS-232 ports (for example, 1/2/2.1).
On the CLI for the 2-port 10GigE (Ethernet) Adapter card or 2-port 10GigE (Ethernet) module, for virtual-port configuration, an Ethernet port is identified as v-port.
The following output examples display the administrative and operational states of adapter cards for all platforms.
For the 7705 SAR-8 Shelf V2:
NOK-1>show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 6
1/1 a12-sdiv2 up provisioned 12
1/2 a4-oc3 up provisioned 4
1/3 a16-chds1v2 up provisioned 16
1/4 a4-chds3v2 up provisioned 4
1/5 a8-1gb-sfp up provisioned 8
1/6 a2-choc3 up provisioned 2
A csmv2-10g up up Active
B csmv2-10g up down Standby
==============================================================================
NOK-1>#
For the 7705 SAR-18:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 12
1/1 aux-alarm up up
1/2 a8-1gb-sfp up up 8
1/3 a8-1gb-sfp up up 8
1/4 a8-1gb-sfp up provisioned 8
1/5 a8-1gb-sfp up provisioned 8
1/6 a32-chds1v2 up up 32
1/7 a32-chds1v2 up up 32
1/8 a8-pmc up up 8
1/9 mw-pic-2 up up 2
1/10 a4-oc3 up provisioned 4
1/11 a4-chds3v2 up provisioned 4
1/12 a2-choc3 up provisioned 2
1/X1 x-10GigE-v2 up provisioned 1
1/X2 x-10GigE-v2 up provisioned 1
1/X3 x-10GigE-v2 up provisioned 1
1/X4 x-10GigE-v2 up provisioned 1
A csm-10g up up Active
B csm-10g up down Standby
==============================================================================
*A:NOK-1#
For the 7705 SAR-A:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 2
1/1 i12-eth-xor up up 12
1/2 i8-chds1 up up 8
A csm-2.5g up up Active
==============================================================================
*A:NOK-1#
For the 7705 SAR-Ax:
*A:sar-Ax# show card state
===============================================================================
Card State
===============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
-------------------------------------------------------------------------------
1 iom-sar up up 2
1/1 i12-1gb-xor up up 12
1/2 i1-gnss up up 1
A csm-2.5g up up Active
===============================================================================
For the 7705 SAR-H:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 3
1/1 i8-1gb up up 8
1/2 p4-combo up up 4
1/3 p4-combo up up 4
A csm-2.5g up up Active
==============================================================================
*A:NOK-1#
For the 7705 SAR-Hc:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 2
1/1 i6-1gb up up 6
1/2 i2-sdi up up 2
A csm-2.5g up up Active
==============================================================================
*A:NOK-1#
For the 7705 SAR-M:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 3
1/1 i7-1gb up up 7
1/2 i16-chds1 up up 16
1/3 p6-eth up up 6
A csm-2.5g up up Active
==============================================================================
*A:ALU-1#
For the 7705 SAR-Wx Ethernet variant:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 1
1/1 i5-1gb-b up up 5
A csm-2.5g up up Active
==============================================================================
*A:NOK-1#
For the 7705 SAR-X:
*A:NOK-1# show card state
==============================================================================
Card State
==============================================================================
Slot/ Provisioned Type Admin Operational Num Num Comments
Id Equipped Type (if different) State State Ports MDA
------------------------------------------------------------------------------
1 iom-sar up up 3
1/1 i8-chds1-x up up 8
1/2 i7-mix-eth up up 7
1/3 i7-mix-eth up up 7
A csm-2.5g up up Active
===============================================================================
*A:NOK-1#