Property name |
Value |
|---|---|
Application name |
OPEN_FLOW |
Event ID |
2001 |
Event name |
tmnxOFFlowEntryInsertFailed |
SNMP notification prefix and OID |
TIMETRA-OPEN-FLOW-MIB.tmnxOpenFlowNotification.1 |
Default severity |
minor |
Message format string |
Failed to add flow-entry for open-flow switch " $tmnxOFSwitchName$" flow-table $tmnxOFFlowTableId$. Flow-table Oper Status: $tmnxOFFlowTableOperStatus$. Failure Reason $tmnxOFNotifyDescription$ |
Cause |
The tmnxOFFlowEntryInsertFailed notification is generated when a flow-entry could not be inserted into an open-flow table. |
Effect |
The flow-entry won't be available in the flow-table. If inserting of a default flow-entry failed, then the value of tmnxOFFlowTableOperStatus is set to 'outOfService (3)'. |
Recovery |
In order to insert the failed flow-entry into flow-table is to change the admin state of an open-flow switch instance to 'outOfService (3)' and then back to 'inService (1)' and try inserting the flow-entry again. |