Monitor Commands

cpm-filter

Syntax

cpm-filter

Context

monitor

Description

This command displays monitor command output for CPM filters.

management-access-filter

Syntax

management-access-filter

Context

monitor

Description

This command enables the context to monitor management access filters.

ip

Syntax

ip entry entry-id [interval seconds] [repeat repeat] [absolute | rate]

Context

monitor>cpm-filter

monitor>management-access-filter

Description

This command enables IP filter monitoring. The statistical information for the specified IP filter entry is displayed at the configured interval until the configured count is reached.

The first screen displays the current statistics related to the specified IP filter. The subsequent statistical information listed for each interval is displayed as a delta to the previous screen output.

When the keyword rate is specified, the rate per second for each statistic is displayed instead of the delta.

Monitor commands are similar to show commands, but only statistical information is displayed. Monitor commands display the selected statistics according to the configured number of times at the interval specified.

Parameters

entry-id

displays information for the specified filter entry ID

Values

1 to 120 (CPM filter)

1 to 9999 (management access filter)

seconds

configures the interval for each display in seconds

Values

3 to 60

Default

10

repeat

configures how many times the command is repeated

Values

1 to 999

Default

10

absolute

displays raw statistics, without processing. No calculations are performed on the delta or rate statistics.

rate

displays the rate per second for each statistic instead of the delta

ipv6

Syntax

ipv6 entry entry-id [interval seconds] [repeat repeat] [absolute | rate]

Context

monitor>cpm-filter

monitor>management-access-filter

Description

This command enables IPv6 filter monitoring. The statistical information for the specified IPv6 filter entry is displayed at the configured interval until the configured count is reached.

The first screen displays the current statistics related to the specified IPv6 filter. The subsequent statistical information listed for each interval is displayed as a delta to the previous screen output.

When the keyword rate is specified, the rate per second for each statistic is displayed instead of the delta.

Monitor commands are similar to show commands, but only statistical information is displayed. Monitor commands display the selected statistics according to the configured number of times at the interval specified.

Parameters

entry-id

displays information for the specified filter entry ID

Values

1 to 120 (CPM filter)

1 to 9999 (management access filter)

seconds

configures the interval for each display in seconds

Values

3 to 60

Default

10

repeat

configures how many times the command is repeated

Values

1 to 999

Default

10

absolute

displays raw statistics, without processing. No calculations are performed on the delta or rate statistics.

rate

displays the rate per second for each statistic instead of the delta

mac

Syntax

mac entry entry-id [interval seconds] [repeat repeat] [absolute | rate]

Context

monitor>cpm-filter

monitor>management-access-filter

Description

This command enables MAC filter monitoring. The statistical information for the specified MAC filter entry is displayed at the configured interval until the configured count is reached.

The first screen displays the current statistics related to the specified MAC filter. The subsequent statistical information listed for each interval is displayed as a delta to the previous screen output.

When the keyword rate is specified, the rate per second for each statistic is displayed instead of the delta.

Monitor commands are similar to show commands, but only statistical information is displayed. Monitor commands display the selected statistics according to the configured number of times at the interval specified.

Parameters

entry-id

displays information for the specified filter entry ID

Values

1 to 120 (CPM filter)

1 to 9999 (management access filter)

seconds

configures the interval for each display in seconds

Values

3 to 60

Default

10

repeat

configures how many times the command is repeated

Values

1 to 999

Default

10

absolute

displays raw statistics, without processing. No calculations are performed on the delta or rate statistics.

rate

displays the rate per second for each statistic instead of the delta