This chapter lists the 7705 SAR compliance with EMC, environmental, and safety standards, telecom standards, and supported protocols:
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
IEEE 1613:2009 + A1:2011  | IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations  | ✓ 1  | ✓ 1  | ✓ 2  | ✓ 1  | ✓ 3  | ✓ 3  | ||||
IEEE 1613.1-2013  | IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Transmission and Distribution Facilities  | ✓ 4  | ✓ 4  | ✓ 5  | ✓ 6  | ✓ 7  | ✓ 7  | ||||
IEEE Std C37.90  | IEEE Standard for relays and relay systems associated with Electric Power Apparatus  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEEE Std C37.90.1  | Surge Withstand Capability (SWC) Tests  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEEE Std C37.90.2  | Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from Transceivers  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEEE Std C37.90.3  | IEEE Standard Electrostatic Discharge Tests for Protective Relays  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
EN 50121-4  | Electromagnetic Compatibility – Part 4: Emission and Immunity of the Signalling and Telecommunications Apparatus  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 62236-4  | Electromagnetic Compatibility – Part 4: Emission and Immunity of the Signalling and Telecommunications Apparatus  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-6-2  | Generic standards – Immunity for industrial environments  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-6-4  | Generic standards – Emissions standard for industrial environments  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-6-5  | Generic standards – immunity for equipment used in power station and substation environment  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61850-3  | Communication networks and systems for power utility automation - Part 3: General requirements  | ✓  | ✓  | ✓  | ✓ 8  | ✓  | ✓  | ||||
IEC/AS 60870.2.1  | Telecontrol equipment and systems. Operating conditions. Power supply and electromagnetic compatibility  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
Notes:
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
IEC 61000-4-2  | Electrostatic discharge immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-4-3  | Radiated electromagnetic field immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-4-4  | Electrical fast transient/burst immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-4-5  | Surge immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-4-6  | Immunity to conducted disturbances  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 61000-4-8  | Power frequency magnetic field immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-9  | Pulse Magnetic field immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-10  | Damped Oscillatory Magnetic Field  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-11  | Voltage dips, short interruptions and voltage variations immunity tests  | ✓  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓  | ✓ 1  | ✓  | ✓  | 
IEC 61000-4-12  | Oscillatory wave immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-16  | Conducted immunity 0 Hz - 150 kHz  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-17  | Ripple on d.c. input power port immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-18  | Damped oscillatory wave immunity test  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-4-29  | Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
IEC 61000-3-2  | Limits for harmonic current emissions (equipment input current <16A per phase)  | ✓  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓  | ✓ 1  | ✓  | ✓  | 
IEC 61000-3-3  | Limits for voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current <16A  | ✓  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓  | ✓ 1  | ✓  | ✓  | 
ITU-T K.20 (DC Ports)  | Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||
ETSI 300 132-2  | Power supply interface at the input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct current (dc)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
ETSI 300 132-3  | Power supply interface at the input to telecommunications equipment; Part 3: Operated by rectified current source, alternating current source or direct current source up to 400V  | ✓  | ✓ 1  | ✓ 1  | ✓ 1  | ✓  | ✓ 1  | ✓  | ✓  | ||
EN 300 386  | Telecommunication network equipment; ElectroMagnetic Compatibility (EMC)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
ES 201 468  | Electromagnetic compatibility and Radio spectrum Matters (ERM); Additional ElectroMagnetic Compatibility (EMC) requirements and resistibility requirements for telecommunications equipment for enhanced availability of service in specific applications  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
EN 55024  | Information technology equipment -Immunity characteristics - Limits and methods of measurements  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
Telcordia GR-1089-CORE  | EMC and Electrical Safety - Generic Criteria for Network Telecommunications Equipment  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
AS/NZS CISPR 22  | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
FCC Part 15, Subpart B  | Radio Frequency devices- Unintentional Radiators (Radiated & Conducted Emissions)  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
ICES-003  | Information Technology Equipment (ITE) — Limits and methods of measurement  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
EN 55022  | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
EN 55032  | Electromagnetic compatibility of multimedia equipment – Emission requirements  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | 
CISPR 22  | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
CISPR 32  | Electromagnetic compatibility of multimedia equipment – Emission requirements  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | 
GS7 EMC  | Electromagnetic Standard Compatibility (BT standard)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |||
KC Notice Emission (KN22) and Immunity (KN24) (South Korea)  | EMS standard: NRRA notice  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |||
KC Notice Emission (KN32) and Immunity (KN35) (South Korea)  | EMS standard: NRRA notice  | ✓  | |||||||||
Notes:
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
IEEE 1613:2009 + A1:2011  | Environmental and Testing Requirements for Communications Networking Devices  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 1  | ✓  | ✓  | ||||
IEC 61850-3  | Communication networks and systems for power utility automation - Part 3: General requirements  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ✓ 2  | ||||
IEC 60068-2-1  | Environmental testing – Part 2-1: Tests – Test A: Cold  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 60068-2-2  | Environmental testing - Part 2-2: Tests - Test B: Dry heat  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 60068-2-30  | Environmental testing - Part 2: Tests. Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC 60255-21-2  | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section Two: Shock and bump tests  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
ETSI 300 753 Class 3.2  | Acoustic noise emitted by telecommunications equipment  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
Telcordia GR-63-CORE  | NEBS Requirements: Physical Protection  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
ETSI EN 300 019-2-1 v2.1.2, Class 1.2  | Specification of environmental tests; Storage  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
ETSI EN 300 019-2-2 V2.1.2, class 2.3  | Specification of environmental tests; Transportation  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
ETSI EN 300 019-2-3 V2.2.2, class 3.2  | Specification of environmental tests; Stationary use at weatherprotected locations  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||
ETSI EN 300 019-2-4 v2.2.2 class T4.1  | Specification of environmental tests; Stationary use at non-weatherprotected locations  | ✓  | ✓  | ||||||||
Telcordia GR-3108-CORE  | Generic Requirements for Network Equipment in the Outside Plant (OSP)  | ✓ 3  | ✓ 3  | ✓ 3  | ✓ 3  | ✓ 3  | ✓ 3  | ✓ 3  | ✓ 4  | ✓ 4  | |
Telcordia GR-950-CORE  | Generic Requirements for ONU Closures and ONU Systems  | ✓  | ✓  | ||||||||
“GR-3108 Class 3 Section 6.2 IEC 60068-2-52 - Severity 3 MIL-STD-810G Method 509.5 EN 60721-3-3 Class 3C4 EN 60068-2-11: Salt Mist EN 50155 Class ST4”  | Conformal Coating 5  | ✓  | ✓  | ✓  | ✓  | ✓  | |||||
Notes:
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
UL/CSA 60950-1  | Information technology equipment - Safety - Part 1: General requirements  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC/EN 60950-1  | Information technology equipment - Safety - Part 1: General requirements  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
UL/CSA 62368-1  | Audio/video, information and communication technology equipment - Part 1: Safety requirements  | ✓  | |||||||||
IEC/EN 62368-1  | Audio/video, information and communication technology equipment - Part 1: Safety requirements  | ✓  | |||||||||
AS/NZS 60950-1  | Information technology equipment - Safety - Part 1: General requirements  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
IEC/EN 60825-1 and 2  | Safety of laser products - Part 1: Equipment classification and requirements Part 2: Safety of optical fibre communication systems (OFCS)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
UL/CSA 60950-22  | Information Technology Equipment - Safety - Part 22: Equipment to be Installed Outdoors  | ✓  | ✓  | ||||||||
CSA–C22.2 No.94  | Special Purpose Enclosures  | ✓  | ✓  | ||||||||
UL50  | Enclosures for Electrical Equipment, Non-Environmental Consideration  | ✓  | ✓  | ||||||||
IEC/EN 60950-22  | Information technology equipment. Equipment to be installed Outdoors.  | ✓  | ✓  | ||||||||
IEC 60529  | Degrees of Protection Provided by Enclosures (IP Code)  | ✓ 1  | ✓ 2  | ✓ 2  | ✓ 1  | ✓ 1  | ✓ 1  | ✓ 2  | ✓ 2  | ✓ 3  | ✓ 3  | 
Notes:
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
IC CS-03 Issue 9  | Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing Aids Compatibility  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
ACTA TIA-968-B  | Telecommunications - Telephone Terminal Equipment - Technical Requirements for Connection of Terminal Equipment to the Telephone Network  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
AS/ACIF S016 (Australia)  | Requirements for Customer Equipment for connection to hierarchical digital interfaces  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
ATIS-06000403  | Network and Customer Installation Interfaces- DS1 Electrical Interfaces  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
ANSI/TIA/EIA-422-B (RS422)  | Electrical Characteristics for balanced voltage digital interfaces circuits  | ✓  | ✓  | ||||||||
ITU-T G.825  | The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH)  | ✓  | ✓  | ||||||||
ITU-T G.703  | Physical/electrical characteristics of hierarchical digital interfaces  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
ITU-T G.712 (E&M)  | Transmission performance characteristics of pulse code modulation channels  | ✓  | ✓  | ||||||||
ITU-T G.957  | Optical interfaces for equipments and systems relating to the synchronous digital hierarchy  | ✓  | ✓  | ||||||||
ITU-T V.24 (RS232)  | List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE)  | ✓  | ✓  | ✓  | ✓  | ||||||
ITU-T V.28 (V35)  | Electrical characteristics for unbalanced double-current interchange circuits  | ✓  | ✓  | ||||||||
ITU-T V.36 (V35)  | Modems for synchronous data transmission using 60-108 kHz group band circuits  | ✓  | ✓  | ||||||||
ITU-T V.11 / X.27 (RS-422)  | Electrical characteristics for balanced double current interchange circuits operating at data signalling rates up to 10 Mbit/s  | ✓  | ✓  | ||||||||
ITU-T X.21 (RS-422)  | Interface between Data Terminal Equipment and Data Circuit-terminating Equipment for synchronous operation on public data networks  | ✓  | ✓  | ||||||||
IEEE 802.3at (POE)  | Data Terminal Equipment Power via the Media Dependent Interfaces Enhancements  | ✓  | ✓  | ✓  | ✓  | ✓  | |||||
Standard  | Title  | Platform  | |||||||||
SAR-X  | SAR-A  | SAR-Ax  | SAR-M  | SAR-8  | SAR-18  | SAR-H  | SAR-Hc  | SAR-W  | SAR-Wx  | ||
EU Directive 2014/30/EU (EMC) (formerly 2004/108/EC)  | Electromagnetic Compatibility (EMC)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
EU Directive 2014/35/EU (LVD) (formerly 2006/95/EC)  | Low Voltage Directive (LVD)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
EU Directive 2012/19/EU (WEEE)  | Waste Electrical and Electronic Equipment (WEEE)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
EU Directive 2011/65/EU (RoHS2)  | Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment (Recast)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | 
CE Mark  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
CRoHS Logo; Ministry of Information Industry order No.39  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
China (MII NAL) Network Access License  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |||||
South Korea (KC Mark)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |||
Australia (RCM Mark)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
Japan (VCCI Mark)  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ||||
NEBS Level 3  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
TL9000 certified  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
ISO 14001 certified  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |
ISO 9001:2008 certified  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | ✓  | |