All
This command displays the ECMP settings for the router.
The following output is an example of ECMP settings information, and Table 119 describes the output fields for the router ECMP settings.
Label | Description |
Instance | The router instance number |
Router Name | The name of the router instance |
ECMP | False — ECMP is disabled for the instance True — ECMP is enabled for the instance |
Configured-ECMP-Routes | The number of ECMP routes configured for path sharing |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command updates the data of the IPoE session identified with the given MAC address and SAP identifier. Optionally the remote ID and circuit ID can be specified to identify the IPoE session to update.
![]() | Note: The changes take effect immediately. |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command provides the parameters to edit lease state information.
service-id: | 1 to 2147483647 |
svc-name: | 64 characters maximum |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command updates the data of the PPP session identified with the given MAC address and SAP identifier. Optionally the remote-id and circuit-id can be specified to identify the IPoE session to update.
![]() | Note: The changes take immediate effect. |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command updates the data of the SLAAC host information.
All
This command displays a system-level summary for EFM-OAM enabled ports. It includes the configuration, action, various states, and soft reset precedence for the protocol.
The following output is an example of EFM-OAM summary information.
All
This command displays service information using the range of egress labels.
If only the mandatory egress-label1 parameter is specified, only services using the specified label are displayed.
If both start-label and end-label parameters are specified, the services using the range of labels X where start-label <= X <= end-label are displayed.
Use the show router ldp bindings command to display dynamic labels.
The following output displays an example of service egress label information.
Table 120 describes show service egress label output fields.
Label | Description |
Svc Id | The ID that identifies a service. |
Sdp Id | The ID that identifies an SDP. |
Type | Indicates whether the SDP binding is a spoke or a mesh. |
I. Lbl | The VC label used by the far-end device to send packets to this device in this service by the SDP. |
E. Lbl | The VC label used by this device to send packets to the far-end device in this service by the SDP. |
Number of bindings found | The total number of SDP bindings that exist within the specified egress label range. |
All
This command displays the number of allocated unique egress PBR destinations.
The following output is an example of filter resource egress PBR destination information.
All
This command displays the egress traffic statistics of the SR policy specified by its color and end-point.
The following output is an example of egress traffic statistics of the SR policy, and Table 121 describes the output fields.
Label | Description |
Color | Indicates the color of the SR policy. |
Endpoint Addr | Indicates the endpoint address of the SR policy. |
Segment-List | Indicates the index of the segment list. |
TunnelId | Indicates the tunnel identifier of the SR policy. |
BSID | Indicates the binding SID value. |
Pkt Count | Indicates the count of packets for the corresponding segment list. |
Octet Count | Indicates the count of octets for the corresponding segment list. |
All
This command clears the egress traffic statistics of the SR policy specified by its color and end-point.
All
This command displays Ethernet Link Management Interface (E-LMI) information.
Table 122 describes the output fields for the show elmi command.
Field | Description |
Link Status | Status of the E-LMI protocol when the elmi mode is set to uni-n. Link Status will indicate up if E-LMI mode is set to "none". |
T391 | Pooling timer used by UNI-C. UNI-N will send the consecutive single EVC asynchronous status messages every (T391/10) rounded to the second interval. |
T392 | Pooling verification timer for UNI-N |
N393 | Status counter for UNI-N. |
Rx Enq. Time | Last time a status inquiry message was received from UNI-C. |
Rx Enq. Msg | Number of status inquiry messages received. |
Rx Check Time | Last time a status inquiry E-LMI check message was received. |
Rx Inv. SeqNum | Counts the number of E-LMI messages received with invalid sequence number. |
Enq Timeouts | Counts the number of T392 timer expired. |
Tx Status Time | Last time a status message was sent by UNI-N. |
Tx Status Msg | Number of status messages sent by UNI-N. |
Tx Check Time | Last time a status E-LMI check message was sent by UNI-N. |
Tx Async Status Msg | Counter for single EVC asynchronous status messages sent by UNI-N. |
Discard Msg | Counter for the status inquiry messages discarded due to errors. |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s, VSR
This command displays NGE information for a key group.
The following output is an example of encryption key group information, and Table 123 describes the fields.
Label | Description |
Encryption Keygroup Configuration Detail | |
Keygroup Id | The key group identifier |
Keygroup Name | The key group name |
Description | The key group description |
Authentication Algo | The authentication algorithm used for the key group |
Encryption Algo | The encryption algorithm used for the key group |
Active Outbound SA | The active outbound SA for the key group |
Activation Time | The date and time that the key group was activated |
Security Associations | |
Spi | The security parameter index for the SA in the key group |
Install Time | The date and time that the SA was installed in the key group |
Key CRC | The CRC for the key belonging to the SA |
Encryption Keygroup Forwarded Statistics | |
Encrypted Pkts | The number of encrypted packets forwarded by the key group |
Encrypted Bytes | The number of encrypted bytes forwarded by the key group |
Decrypted Pkts | The number of decrypted packets forwarded by the key group |
Decrypted Bytes | The number of decrypted bytes forwarded by the key group |
Encryption Keygroup Outbound Discarded Statistics (Pkts) | |
Total Discard | The total number of outbound packets discarded by the key group |
Unsupported Uplink | The total number of outbound packets discarded by the key group due to an unsupported uplink |
Enqueue Error | The total number of outbound packets discarded by the key group due to an enqueuing error |
Other | The total number of outbound packets discarded by the key group due to some other reason, such as an internal configuration error (for example, a key group that points to an SA, but the SA is not valid) |
Encryption Keygroup Inbound Discarded Statistics (Pkts) | |
Total Discard | The total number of inbound packets discarded by the key group |
Invalid Spi | The total number of inbound packets discarded by the key group due to an invalid SPI |
Authentication Failure * | The total number of inbound packets discarded by the key group due to an authorization failure |
Control Word Mismatch | The total number of inbound packets discarded by the key group due to a control word (CW) mismatch between the encrypted (protected) CW in the ESP payload and the CW that is not encrypted |
Padding Error | The total number of inbound packets discarded by the key group due to a padding error |
Enqueue Error | The total number of inbound packets discarded by the key group due to an enqueuing error |
Other | The total number of inbound packets discarded by the key group due to some other reason (for example, an incoming packet length is incorrect) |
SDP Keygroup Association Table | |
SDP ID | The SDP ID |
Direction | The direction in which key group authentication and encryption occurs for traffic on the SDP |
Inbound Keygroup SDP Association Count | The number of SDPs configured to use inbound SA |
Outbound Keygroup SDP Association Count | The number of SDPs configured to use outbound SA |
VPRN Keygroup Association Table | |
VPRN SVC ID | The VPRN service identifier |
Direction | The direction in which key group authentication and encryption occurs for traffic on the VPRN |
Inbound Keygroup VPRN Association Count | The number of VPRNs configured to use inbound SA |
Outbound Keygroup VPRN Association Count | The number of VPRNs configured to use outbound SA |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s, VSR
This command clears NGE information for a key group.
All
This command displays service endpoint information.
The following output is an example of service endpoint information.
All
This command displays the MPLS forwarding policy endpoint information.
Table 124 describes MPLS endpoint output fields.
Label | Description |
Endpoint | Specifies the endpoint IP address. |
Preference | Specifies the preference. |
Policy Name | Specifies the MPLS forwarding policies binding label name. |
Active | Specifies the active state (Y | N). |
InactiveReason | Specifies the inactive reason. |
Last Updated | Specifies the date and time of the last update. |
Num Grps | Specifies the number of groups. |
OperState | Specifies the operational state (up | down). |
Metric | Specifies the metric value. |
TTM Preference | Specifies the TTM preference value. |
Revert Timer | Specifies the revert timer value. |
Path Pref | Specifies the path preference. |
Retry Count | Specifies the retry count. |
Next Retry In | Specifies the next retry value. |
Next-hop Group | Specifies the next-hop group. |
Resolution Type | Specifies the resolution type (direct | indirect). |
Oper State | Specifies the operational state (down | up). |
Oper Down Reas* | Specifies the reason for being operationally down. |
Num Revert | Specifies the number of reverts. |
Num Failover | Specifies the number of failovers. |
Next Revert In | Specifies the next revert interval. |
Weight | Specifies the weight value. |
Primary | Specifies the IP address of the primary next-hop. |
Resolved | Specifies the resolved status (false | true). |
Down Reason | Specifies the down reason. |
Backup | Specifies the IP address of the backup next-hop. |
StatsOperState | Specifies if a statistic index is allocated to the next-hop. |
EgrStatsState | Specifies if all next-hops have a statistic index allocated. |
All
This command enables the context to perform IP filter entry operations.
All
This command enables the context to perform IPv6 filter entry operations.
All
This command enables the context to perform MAC filter entry operations.
All
This command displays Epipe services associated with the B-VPLS service. The command only applies when the service is a B-VPLS.
The following is an example of Epipe service information.
All
This command will display the egress port that will be used to transmit traffic associated with the displayed Epipe service(s). The information displayed shows the egress port for traffic traveling from SAP to egress SDP or SAP.
This command will support Epipe services with the following combinations:
The command can be executed by specifying either a service ID, service-ID range or an ingress LAG ID.
This command will not display the egress port for traffic traveling from the SDP to egress SAP. This command also does not work with services that use policers or shared queues and also does not support PBB services.
This command replaces the command tools dump epipe-map-to-network, which has been deprecated.
This command displays http-error-redirect error-codes.
The following output example shows HTTP error redirect error code information, and Table 125 describes the fields.
Label | Description |
Description | Describes the error |
Default | Indicates what the default is for the error |
custom-msg-size (Custom Message Size) | The size of the message |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command dumps various error counters related to TWAMP server and TWAMP test.
The following output is an example of various error counters related to TWAMP server and TWAMP test.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command clears all errors in the circular buffer.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command clears all errors in the circular buffer.
This command shows the remote Ethernet Segment B-MACs as well as the BGP-EVPN MPLS destinations associated to them.
All
When a filter with an action forward esi is successfully added to a VPLS service and the PE receives an EVPN Auto-Discovery route for the configured ESI, this command displays the PBR VXLAN bindings auto-created, including the ESI, the VXLAN VTEP:VNI and the status of the binding.
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s
This command displays ESA details.
The following are output examples for this command.
Table 126 describes the ESA output fields.
Label | Description |
ESA | The ESA identification number |
Admin State | up — Administratively up |
down — Administratively down | |
Operational State | up — Operationally up |
down — Operationally down | |
booting | |
failed | |
provisioned | |
unprovisioned | |
fwUpgrade — Firmware upgrade | |
Oper flags | Operational flag of the ESA |
IOM Host Port | The IOM host port in slot/mda/port format |
Hardware Data | Detailed hardware data about the ESA |
VM | The VM identification number |
VM Type | The VM type (aa, bb, or tunnel) |
Cores | The number of cores of the ESA-VM |
Memory (GB) | The memory on the ESA-VM |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s
This command clears the statistics or status pertaining to the specified ESA.
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s
This command displays ESA-VM details.
The following are output examples for this command.
Table 127 describes the ESA-VM output fields.
Label | Description |
ESA | The ESA identification number |
VM | The VM identification number |
VM Type | The VM type (aa, bb, or tunnel) |
Cores | The number of cores of the ESA-VM |
Memory (GB) | The memory on the ESA-VM |
Admin State | up — Administratively up |
down — Administratively down | |
Operational State | up — Operationally up |
down — Operationally down | |
booting | |
failed | |
provisioned | |
unprovisioned | |
IOM Host Port | The IOM host port in slot/mda/port format |
Oper flags | The operational flags for the ESA-VM |
Virtual Core Role | The virtual core role (Mgmt-#, Worker-#, Idle-#, Scheduler-#, Nic-#) |
Virtual Core Id | The Virtual Core identification number |
Current % | The current processing load of the virtual core |
15min Average % | The 15 minute average processing load of the virtual core |
All-time Peak % | The all-time peak processing load of the virtual core |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s
This command clears the statistics or status pertaining to the specified ESA-VM.
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s
This command clears the statistics or status pertaining to the specified ESA-VM.
This command shows the remote Ethernet Segment identifiers (ESIs) as well as the BGP-EVPN MPLS destinations associated to them.
All
This command enables the context to configure a loopback on Ethernet SAPs or MPLS SDP bindings.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command enables the context to display eth-cfm information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command enables the context to display CFM information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command enables the context to configure debugging for Ethernet Connectivity Fault Management.
7450 ESS, 7750 SR-14s, 7750 SR-7/12/12e, 7750 SR-7s, 7950 XRS
This command displays sources exceeding their eth-cfm-monitoring rate limit.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command performs Ethernet ring operations.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command displays Ethernet Ring information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command displays Ethernet Ring information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command displays information about configured Ethernet satellites. If a sat-id is specified, this command displays information only about the specified Ethernet satellite.
The following output is an example of Ethernet satellite information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command displays information about configured L2TPv3 Ethernet tunnels. These Ethernet tunnels are the L2TPv3 sessions setup between the local private L2 SAP and the far end device.
If this command is executed without any parameters, then a list of all configured Ethernet tunnels are displayed.
If this command is executed with a tunnel group name or a VC-ID, then a detailed view of the associated Ethernet tunnel is displayed.
The following output is an example of L2TPv3 Ethernet tunnel information
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command displays Ethernet tunnel information. Any data SAP missing a tag for a defined path has the EthTunTagMismatch flag generated. In the example provided below, SAP eth-tunnel-1:1 does not have the tag for path 2 configured. Therefore, it is operationally down with the reason indicated by the EthTunTagMismatch flag.
The following output is an example of Ethernet tunnel information, and Table 128 describes the output fields.
Field | Description |
Tunnel Id | Numeric value from 1 to 64. |
Admin State | Up — The eth tunnel is administratively up. Down — The eth tunnel is administratively down. |
Oper State | Up — The eth tunnel is operationally up. Down — The eth tunnel is operationally down. |
Protection Type | Two options: g8031-1to1 — Two members are allowed, but only one of them is active at one point in time. loadsharing — Multiple members can be active at one point in time. |
Active Paths | Only two paths are supported. |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS
This command displays Ethernet tunnel information.
The following output is an example of Ethernet tunnel information.
All
This command enables the context to display system-specific Ethernet information.
This command enables the context to display the Ethernet-Segment parameters.
The following shows BGP EVPN Ethernet-Segment information.
All
This command shows the computed DF PE for a specified EVI or ISID when the evi or isid parameters are selected, respectively. When the local-bias parameter is used, the output lists the PEs that are in the candidate DF Election list for the ES, and whether local bias procedures are enabled on them.
The PE can only enable local bias procedures on up to three PEs that are attached to the same ES and use multihomed VXLAN services. If more than three PEs exists, the PEs are ordered by either lowest IP (if service-carving auto is used in the ES) or lowest preference (if preference-based service-carving is used) and only the top three PEs are considered for local bias.
The following is an example of Ethernet Segment information.
All
This command displays the same information shown in the show service ID base context, with the addition of the role of each object in the VPLS E-Tree service.
The following labels identify the configuration of the SAPs and SDP bindings:
The following is an example of VPLS E-Tree information.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command re-evaluates the mapping between authentication strings such as the SLA profile string and the actual profiles for the identified IPoE sessions.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command evaluates lease state.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command re-applies the managed SAP policy to the managed SAP identified by the specified sap-id or to all managed SAPs associated with the specified msap-policy name.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command evaluates PPP sessions.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command evaluates all bonding contexts and recalculates all reference rates. This command can be useful in handling changes that are not automatically tracked, such as adapting a scheduler rate in a QoS policy.
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command evaluates the SLAAC host.
ipv6-prefix | x:x:x:x:x:x:x:x (eight 16-bit pieces) |
x:x:x:x:x:x:d.d.d.d |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This tools command performs the execution of a dynamic service script action as if the corresponding RADIUS attributes were received from RADIUS. It is possible to setup, modify or teardown a dynamic service associated with the specified control channel.
All
The command enables the user to test their setup, and modify and tear down Python scripts in a lab environment without the need to be connected to a VSD. The successful execution of the command for action setup will create a VSD domain and the corresponding configuration, just as the system would do when the parameters are received from VSD.
All
This command displays Ethernet Virtual Connections (EVC). No argument displays all the EVC on the service router. The port and VLAN arguments display information related to EVC associated with the port and VLAN.
The following output is an example of E-LMI EVC information, and Table 129 describes the output fields.
Field | Description |
Port | Port identifier. |
Vlan | Vlan identifier. |
Status | New-Act — New and active. Act — Active. |
Type | Connection type. |
EVC Id | EVC identifier. |
All
This command displays event control settings for events including whether the event is suppressed or generated and the severity level for the event.
If no options are specified all events, alarms and traps are listed.
The following is an example of event control information.
Table 130 describes the output fields for the event control.
The following is a sample output:
Label | Description |
Application | The application name. |
ID# | The event ID number within the application. L ID# An “L” in front of an ID represents event types that do not generate an associated SNMP notification. Most events do generate a notification, only the exceptions are marked with a preceding “L”. |
Event Name | The event name. |
P | CL — The event has a cleared severity or priority. CR — The event has critical severity or priority. IN — The event has indeterminate severity or priority. MA — The event has major severity or priority. MI — The event has minor severity or priority. WA — The event has warning severity or priority. |
g/s | gen — The event will be generated or logged by event control. sup — The event will be suppressed or dropped by event control. thr — Specifies that throttling is enabled. |
Logged | The number of events logged or generated. |
Dropped | The number of events dropped/suppressed. |
Severity | The severity level of the event (cleared, indeterminate, critical, major, minor, or warning). |
Generated | Indicates whether the log event is enabled (true) or suppressed (false). |
Count | The number of events logged or generated. |
Drop count | The number of events dropped/suppressed. |
Throttle | Indicates whether the event is subject to global throttling (true or false). |
Specific throttle | Indicates whether the event is subject to specific per event throttling (true or false). |
Specific throttle limit | The configured number of events per interval for specific throttling. |
Specific throttle interval (s) | The configured interval over which the specific throttling limit is applied. |
Specific throttle by default | Indicates whether the specific throttling is enabled or not when it has not been explicitly configured. |
Specific throttle limit default | The default number of events per-interval for specific throttling of this event. |
Specific throttle interval default (s) | The default interval over which the specific default throttling limit is applied. |
Repeat | Specifies that the log event should be repeated every minute until the underlying condition is cleared. |
All
This command enables the context to display Event Handling System (EHS) information.
All
This command enables the context to clear Event Handling System (EHS) information.
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s, VSR
This command displays event log information.
The following is a sample output displaying event log information:
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s, VSR
This command displays application-assurance event-log information.
All
This command displays an event's (or all events) common parameters and specific parameters. This allows a user to know what parameters can be passed from a triggering event to the triggered EHS script.
The following is an example of log event parameter information.
All
This command enables the context for the global evpn parameters.
This command clears a duplicate MAC and restarts the MAC duplication process. It also clears black-hole MACs.
This command shows the maximum number of EVPN-tunnel interface IP next hops per R-VPLS as well as the current usage for a specified R-VPLS service.
The following is an example of tools dump EVPN usage information.
All
This command shows the remote EVPN-MPLS tunnel endpoints in the system.
All
This command displays the existing EVPN-MPLS destinations for a specified service and all related information. The command allows filtering based on esi (for EVPN multi-homing) and es-bmac (for PBB-EVPN multi-homing) to display the EVPN-MPLS destinations associated to an Ethernet Segment Identifier (ESI).
Table 131 describes the EVPN-MPLS output fields.
Label | Description |
vBmacAddr | Displays the vBmac address. |
Num. Macs | Displays the number of MACs. |
Last Change | Indicates the time of the most recent state changes. |
TEP Address | Displays the TEP address. |
Egr Label | Displays the egress label. |
Transport | Displays the transport type. |
Number of entries | Indicates the number of entries. |
Eth SegId | Displays the Ethernet Segment ID |
Transport:Tnl-Id | Displays the tunnel type and tunnel ID of the EVPN-MPLS entry. |
Transport:Tnl | Displays the transport tunnel. |
Num. MAC | Displays the number of MACs. |
Mcast | Displays the multicast information. |
Sup BCast Domain | Displays the Sup BCast Domain. |
All
7450 ESS, 7750 SR-14s, 7750 SR-7/12/12e, 7750 SR-7s, 7950 XRS
This command displays sources exceeding their per-source rate limit.
7450 ESS, 7750 SR-14s, 7750 SR-7/12/12e, 7750 SR-7s, 7950 XRS
This command clears the records of sources exceeding their per-source rate limit.
7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e
This command performs an exercise request on the protection or working circuit.
aps-id | aps-group-id | |
aps | keyword | |
group-id | 1 to 128 |
All
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, VSR
This command displays explicit subscriber mappings.
The following is an example of subscriber management explicit subscriber map information.
Table 133 describes subscriber management explicit subscriber map output fields.
Field | Description |
Key | The explicit subscriber mapping |
Number of Explicit Subscriber Mappings | The number of configured explicit subscriber mappings |
All
This command re-evaluates route policies participating in the export mechanism, either as importers or exporters of routes.
All
This command re-evaluates all effective export policies.
All
This command re-evaluates RIP export policies.
All
This command re-evaluates RIPng export policies.
All
This command displays extranet interface information.