The show>system>information command shows the current value of the bad/good exec URLs and indicates whether a post-boot configuration extension file was executed when the system was booted. If an extension file was executed, the show>system>information command also indicates if it completed successfully or not.
The following is an example for the 7750 SR:
ALA-12>config>system# show system information
===============================================================================
System Information
===============================================================================
System Name : ALA-12
System Contact : Fred Information Technology
System Location : Bldg.1-floor 2-Room 201
System Coordinates : N 45 58 23, W 34 56 12
System Up Time : 1 days, 04:59:33.56 (hr:min:sec)
SNMP Port : 161
SNMP Engine ID : 0000197f000000000467ff00
SNMP Max Message Size : 1500
SNMP Admin State : Disabled
SNMP Oper State : Disabled
SNMP Index Boot Status : Not Persistent
BOF Source : cf1:
Image Source : primary
Config Source : primary
Last Booted Config File: ftp://test:test@192.168.xx.xxx/./12.cfg
Last Boot Cfg Version : THU MAR 04 22:39:03 2004 UTC
Last Boot Config Header: # TiMOS-L-14.0.B1-217 boot/
i386 Nokia 7750 SR Copyright (c)
2000-2016 Nokia.
# All rights reserved. All use subject to applicable license
agreements.
# Built on Wed Jul 13 19:08:56 PDT 2016 by builder in /
rel14.0/b1/B1-217/panos/main
Last Boot Index Version: N/A
Last Boot Index Header : N/A
Last Saved Config : N/A
Time Last Saved : N/A
Changes Since Last Save: Yes
Time Last Modified : 2004/03/06 03:30:45
Max Cfg/BOF Backup Rev : 7
Cfg-OK Script : ftp://test:test@192.168.xx.xxx/./ok.cfg
Cfg-OK Script Status : not used
Cfg-Fail Script : ftp://test:test@192.168.xx.xxx/./fail.cfg
Cfg-Fail Script Status : not used
Management IP Addr : 192.168.xx.xxx/20
DNS Server : 192.168.1.254
DNS Domain : eng.timetra.com
BOF Static Routes :
To Next Hop
172.16.0.0/22 192.168.1.251
ICMP Vendor Enhancement: Disabled
ATM Location ID : 01:00:00:00:00:11:00:00:00:00:00:00:00:00:00:00
===============================================================================
ALA-12>config>system#
When executing a post-boot configuration extension file, status messages are output to the CONSOLE screen before the ‟Login” prompt.
Following is an example of a failed bootup configuration that caused a boot-bad-exec file containing another error to be executed:
Attempting to exec configuration file:
’ftp://test:test@192.168.xx.xxx/./12.cfg’ ...
System Configuration
Log Configuration
MAJOR: CLI #1009 An error occurred while processing a CLI command -
File ftp://test:test@192.168.xx.xxx/./12.cfg, Line 195: Command "log" failed.
CRITICAL: CLI #1002 An error occurred while processing the configuration file.
The system configuration is missing or incomplete.
MAJOR: CLI #1008 The SNMP daemon is disabled.
If desired, enable SNMP with the ’config>system>snmp no shutdown’ command.
Attempting to exec configuration failure extension file:
’ftp://test:test@192.168.xx.xxx/./fail.cfg’ ...
Config fail extension
Enabling SNMP daemon
MAJOR: CLI #1009 An error occurred while processing a CLI command -
File ftp://test:test@192.168.xx.xxx/./fail.cfg, Line 5: Command "abc log" failed.
TiMOS-L-14.0.B1-217 boot/i386 Nokia 7750 SR Copyright (c) 2000-2016 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Wed Jul 13 19:08:56 PDT 2016 by builder in /rel14.0/b1/B1-217/panos/main
Login: