The most basic configuration must specify the following:
chassis slot
line card type (must be an allowed card type)
MDA slot
MDA (must be an allowed MDA type)
specific port to configure
The following is an example of card configuration for the 7750 SR:
A:PE-1# admin display-config | match "Card Configuration" post-lines 28
echo "Card Configuration"
#--------------------------------------------------
card 2
card-type imm5-10gb-xfp
mda 1
no shutdown
exit
no shutdown
exit
card 3
card-type iom4-e
mda 1
mda-type me10-10gb-sfp+
no shutdown
exit
mda 2
mda-type me1-100gb-cfp2
no shutdown
exit
no shutdown
exit
card 5
card-type imm5-10gb-xfp
mda 1
no shutdown
exit
no shutdown
exit
#--------------------------------------------------
A:PE-1#
The following is an example of card configurations for the 7950 XRS:
A:7950 XRS-20# configure card 1
A:7950 XRS-20>config>card# info
----------------------------------------------
card-type xcm-x20
mda 1
mda-type cx20-10g-sfp
no shutdown
exit
mda 2
mda-type cx2-100g-cfp
no shutdown
exit
no shutdown
----------------------------------------------