Depending on location and law enforcement preferences, the node can be configured to save all LI data on local media. If the operator saves this data then when starting or restarting the system the configuration file is processed first and then the LI configuration is restarted.
When permitted to save the data, the data is encrypted using AES. The encryption key is unique per system and is not visible to any administrator.
To save LI data locally, the option must be configured in the bof>li-local-save context. Enabling this option is only be applied after a system reboot.
If an LI save is permitted, then only a local save is permitted and, by default, it is saved to Compact Flash 3 with the filename of li.cfg. An explicit save command under the config>li context must be executed to save the LI. An LI administrator with privileges to configure LI, can execute the li.cfg file.