Facility alarms for children objects is not raised for failure of a parent object. For example, when an MDA or XMA fails (or is shutdown) there is not a set of port facility alarms raised.
When a parent facility alarm is cleared, children facility alarms that are still in occurrence on the node appears in the active facility alarms list. For example, when a port fails there is a port facility alarm, but if the MDA or XMA is later shutdown the port alarm is cleared (and a card alarm is active for the MDA or XMA). If the MDA or XMA comes back into service, and the port is still down, then a port alarm becomes active once again.
The supported facility alarm hierarchy is as follows (parent objects that are down cause alarms in all children to be masked):
CPM -> Compact Flash
CCM -> Compact Flash
IOM/IMM -> MDA -> Port -> Channel
XCM -> XMA -> Port