configure
— chassis keyword chassis-number number
— apply-groups reference
— apply-groups-exclude reference
— monitor-filter-door boolean
— peq number
— admin-state keyword
— apply-groups reference
— apply-groups-exclude reference
— input-power-mode number
— peq-type keyword
— power-connection-module number
— apply-groups reference
— apply-groups-exclude reference
— pcm-type keyword
— power-shelf number
— admin-state keyword
— apply-groups reference
— apply-groups-exclude reference
— description string
— power-module number
— admin-state keyword
— apply-groups reference
— apply-groups-exclude reference
— power-module-type keyword
— power-shelf-type keyword
— power-supply number
— apply-groups reference
— apply-groups-exclude reference
— power-supply-type keyword
Synopsis | Enter the chassis list instance | |
Context | configure chassis keyword chassis-number number | |
Tree | chassis | |
Introduced | 16.0.R1 | |
Platforms |
All |
Synopsis | Functional use of the physical chassis | |
Context | configure chassis keyword chassis-number number | |
Options | ||
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
All |
Synopsis | Unique index to identify this physical chassis | |
Context | configure chassis keyword chassis-number number | |
Range | 1 to 100 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
All |
Synopsis | Allow filter door monitoring | |
Context | configure chassis keyword chassis-number number monitor-filter-door boolean | |
Tree | monitor-filter-door | |
Default | false | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-7s, 7750 SR-14s |
Synopsis | Enter the peq list instance | |
Context | configure chassis keyword chassis-number number peq number | |
Tree | peq | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-12e, 7950 XRS |
Synopsis | Unique identifier index for a power supply tray in the chassis | |
Context | configure chassis keyword chassis-number number peq number | |
Range | 1 to 31 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
7750 SR-12e, 7950 XRS |
Synopsis | Administrative state of the PEQ | |
Context | configure chassis keyword chassis-number number peq number admin-state keyword | |
Tree | admin-state | |
Default | enable | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-12e, 7950 XRS |
Synopsis | Input power mode of the PEQ | |
Context | configure chassis keyword chassis-number number peq number input-power-mode number | |
Tree | input-power-mode | |
Range | 60 | 80 | |
Units | amperes | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-12e, 7950 XRS |
WARNING:
Modifying this element recreates the parent element automatically for the new value to take effect. |
||
Synopsis | APEQ type | |
Context | configure chassis keyword chassis-number number peq number peq-type keyword | |
Tree | peq-type | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-12e, 7950 XRS |
Synopsis | Enter the power-connection-module list instance | |
Context | configure chassis keyword chassis-number number power-connection-module number | |
Tree | power-connection-module | |
Introduced | 16.0.R1 | |
Platforms |
7950 XRS-20e |
Synopsis | Unique identifier index for a power control module in the chassis | |
Context | configure chassis keyword chassis-number number power-connection-module number | |
Range | 1 to 12 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
7950 XRS-20e |
WARNING:
Modifying this element recreates the parent element automatically for the new value to take effect. |
||
Synopsis | PCM type | |
Context | configure chassis keyword chassis-number number power-connection-module number pcm-type keyword | |
Tree | pcm-type | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7950 XRS-20e |
Synopsis | Enter the power-shelf list instance | |
Context | configure chassis keyword chassis-number number power-shelf number | |
Tree | power-shelf | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Unique identifier index for a power shelf in chassis | |
Context | configure chassis keyword chassis-number number power-shelf number | |
Range | 1 to 2 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Administrative state of the power shelf | |
Context | configure chassis keyword chassis-number number power-shelf number admin-state keyword | |
Tree | admin-state | |
Default | enable | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Text description | |
Context | configure chassis keyword chassis-number number power-shelf number description string | |
Tree | description | |
String Length | 1 to 80 | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Enter the power-module list instance | |
Context | configure chassis keyword chassis-number number power-shelf number power-module number | |
Tree | power-module | |
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Unique identifier for a power module in chassis | |
Context | configure chassis keyword chassis-number number power-shelf number power-module number | |
Range | 1 to 12 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Administrative state of the power module | |
Context | configure chassis keyword chassis-number number power-shelf number power-module number admin-state keyword | |
Tree | admin-state | |
Default | enable | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
WARNING:
Modifying this element recreates the parent element automatically for the new value to take effect. |
||
Synopsis | Power module type | |
Context | configure chassis keyword chassis-number number power-shelf number power-module number power-module-type keyword | |
Tree | power-module-type | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
WARNING:
Modifying this element recreates the parent element automatically for the new value to take effect. |
||
Synopsis | Power shelf type | |
Context | configure chassis keyword chassis-number number power-shelf number power-shelf-type keyword | |
Tree | power-shelf-type | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |
7750 SR-s |
Synopsis | Enter the power-supply list instance | |
Context | configure chassis keyword chassis-number number power-supply number | |
Tree | power-supply | |
Introduced | 16.0.R1 | |
Platforms |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS |
Synopsis | Unique identifier index for a power supply tray in the chassis | |
Context | configure chassis keyword chassis-number number power-supply number | |
Range | 1 to 31 | |
Notes |
This element is part of a list key. |
|
Introduced | 16.0.R1 | |
Platforms |
7450 ESS, 7750 SR, 7750 SR-a, 7750 SR-e, 7750 SR-s, 7950 XRS |
Synopsis | Power supply type | |
Context | configure chassis keyword chassis-number number power-supply number power-supply-type keyword | |
Tree | power-supply-type | |
Default | auto | |
Options | ||
Introduced | 16.0.R1 | |
Platforms |