aps commands

configure 
aps number 
advertise-interval number
annexb 
wait-to-restore-time number
working-circuit reference
apply-groups reference
apply-groups-exclude reference
hold-time number
neighbor (ipv4-address-no-zone | ipv6-address-no-zone)
protect-circuit reference
revert 
time number
switching-mode keyword
working-circuit reference

aps command descriptions

aps [group-id] number

  Synopsis Enter the aps list instance
  Context configure aps number
  Tree aps
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

[group-id] number

  Synopsis APS group ID
  Context configure aps number
  Range 1 to 128
 

Notes

This element is part of a list key.

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

advertise-interval number

  Synopsis Time between subsequent advertisement messages
  Context configure aps number advertise-interval number
  Tree advertise-interval
  Range 10 to 650
  Default 10
  Units deciseconds
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

annexb

  Synopsis Enable the annexb context
  Context configure aps number annexb
  Tree annexb
 

Notes

The following elements are part of a choice: annexb or (neighbor, protect-circuit, revert, and working-circuit).

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

wait-to-restore-time number
  Synopsis Annex B mode operation wait to restore time
  Context configure aps number annexb wait-to-restore-time number
  Tree wait-to-restore-time
 

Description

This command specifies the delay after which the newly active section becomes the primary section after a switchover from the primary section to the secondary section occurs and the switch request clears normally.

  Range 0 to 3600
  Default 300
  Units seconds
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

working-circuit reference
  Synopsis Working circuit port for the APS group
  Context configure aps number annexb working-circuit reference
  Tree working-circuit
 

Reference

configure port string

  Max. Instances 2
 

Notes

This element is ordered by the user.

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

hold-time number

  Synopsis Time to wait for an advertisement packet
  Context configure aps number hold-time number
  Tree hold-time
  Range 10 to 650
  Default 30
  Units deciseconds
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

neighbor (ipv4-address-no-zone | ipv6-address-no-zone)

  Synopsis Neighbor IP address for multi-chassis APS
  Context configure aps number neighbor (ipv4-address-no-zone | ipv6-address-no-zone)
  Tree neighbor
 

Notes

The following elements are part of a choice: annexb or (neighbor, protect-circuit, revert, and working-circuit).

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

protect-circuit reference

  Synopsis Protection circuit port for the APS group
  Context configure aps number protect-circuit reference
  Tree protect-circuit
 

Reference

configure port string

 

Notes

The following elements are part of a choice: annexb or (neighbor, protect-circuit, revert, and working-circuit).

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

revert

  Synopsis Enable the revert context
  Context configure aps number revert
  Tree revert
 

Notes

The following elements are part of a choice: annexb or (neighbor, protect-circuit, revert, and working-circuit).

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

time number
  Synopsis Wait time before switching back to the working circuit
  Context configure aps number revert time number
  Tree time
  Range 0 | 60 to 3600
  Default 300
  Units seconds
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

switching-mode keyword

  Synopsis Switching mode for the APS port
  Context configure aps number switching-mode keyword
  Tree switching-mode
  Default bi-directional
  Options uni-directional, bi-directional
  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e

working-circuit reference

  Synopsis Working circuit port for the APS group
  Context configure aps number working-circuit reference
  Tree working-circuit
 

Reference

configure port string

 

Notes

The following elements are part of a choice: annexb or (neighbor, protect-circuit, revert, and working-circuit).

  Introduced 20.10.R1
 

Platforms

7450 ESS, 7750 SR-7/12/12e, 7750 SR-a, 7750 SR-e