No Shutdown Port

A no shutdown command executed on the in-band port to which the trap-target address is bound causes the route to that trap target to be re-added to the route table. When the SNMP trap module is notified of this event, it resends the notifications that were missed while there was no route to the trap-target address.

configure# port 1/1/1 no shutdown # # tools perform log test-event

After the notifications have been replayed the Replay from field indicates n/a because there are no more notifications waiting to be replayed and the Last replay field timestamp has been updated.

*A:SetupCLI# show log snmp-trap-group 44
===============================================================================
SNMP Trap Group 44
===============================================================================
Description : none
-------------------------------------------------------------------------------
Name        : xyz-test
Address     : 10.10.10.3
Port        : 162
Version     : v2c
Community   : xyztesting
Sec. Level  : none
Replay      : enabled
Replay from : n/a
Last replay : 04/22/2008 18:52:36
-------------------------------------------------------------------------------
Name        : test2
Address     : 10.20.20.5
Port        : 162
Version     : v2c
Community   : xyztesting
Sec. Level  : none
Replay      : disabled
Replay from : n/a
Last replay : never
===============================================================================
*A:SetupCLI# 

A display of the event log shows that it is no longer waiting to replay notifications to one or more of its trap target addresses. An event message has been written to the logger that indicates the replay to the trap-target address has happened and displays the notification sequence ID of the first and last replayed notifications.

*A:SetupCLI# show log log-id 44
===============================================================================
Event Log 44
===============================================================================
SNMP Log contents  [size=100   next event=3827  (wrapped)]

3826 2008/04/22 23:42:02.15 UTC MAJOR: LOGGER #2015 Base Log-id 44
"Missed events 3819 to 3825 from Log-id 44 have been resent to SNMP notification
 target address 10.10.10.3."

3825 2008/04/22 23:42:02.15 UTC INDETERMINATE: LOGGER #2011 Base Event Test
"Test event has been generated with system object identifier tmnxModelSR12Reg.
System description: TiMOS-B-0.0.private both/i386 Nokia 7750 SR Copyright (c) 
2000-2016 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Tue Apr 22 14:41:18 PDT 2008 by test123 in /test123/ws/panos/main"

3824 2008/04/22 23:41:49.82 UTC WARNING: SYSTEM #2009 Base IP
"Status of vRtrIfTable: router Base (index 1) interface xyz-test (index 35) changed
 administrative state: inService, operational state: inService"

3823 2008/04/22 23:41:49.82 UTC WARNING: SNMP #2005 Base xyz-test
"Interface xyz-test is operational"