The no form of the event-control command returns modified values back to the default values.
Use the following CLI syntax to modify event control parameters:
config>log
no event-control application [event-name |event-
number]
The following displays an example of the command usage to return to the default values:
Example:config# log
config>log# no event-control "bgp" 2001
config>log# no event-control "bgp" 2002
config>log# no event-control "bgp" 2014
A:ALA-12>config>log# info detail
----------------------------------------------
#------------------------------------------
echo "Log Configuration"
#------------------------------------------
event-control "bgp" 2001 generate minor
event-control "bgp" 2002 generate warning
event-control "bgp" 2003 generate warning
event-control "bgp" 2004 generate critical
event-control "bgp" 2005 generate warning
event-control "bgp" 2006 generate warning
event-control "bgp" 2007 generate warning
event-control "bgp" 2008 generate warning
event-control "bgp" 2009 generate warning
event-control "bgp" 2010 generate warning
event-control "bgp" 2011 generate warning
event-control "bgp" 2012 generate warning
event-control "bgp" 2013 generate warning
event-control "bgp" 2014 generate warning
event-control "bgp" 2015 generate critical
event-control "bgp" 2016 generate warning
...
----------------------------------------------
A:ALA-12>config>log#