Fan controller debug commands

fan-stats

Syntax

fan-stats

Context

tools>dump

Platforms

7210 SAS-D ETR

Description

This command provides details of the fan operation.

Output

The following output is an example of fan-stats information, and Table: Output fields: show fan statistics describes the output fields.

Sample output
A:7210SAS# tools dump system fan-stats 

Fan Configuration Mode : Auto
Fan Status : Off
Auto Mode Duration : 70 hr:24 min
Fan ON Count : 2
Note:

When the fan mode is changed by the user, the values displayed above are automatically reset by the software.

Table: Output fields: show fan statistics

Label

Description

Fan Configuration Mode

Displays the user configured mode for fan operation

It can be On/Off/Auto

Fan Status

Displays the current status of the fan

It can be On/Off

Auto Mode Duration

Displays the total duration since the fan has been in auto mode

Displayed in HH:MM format to indicate hours and minutes

Valid only when the Fan configuration mode is auto

Fan ON count

Displays the total number of times the Fan has been switched 'ON' in auto mode

Valid only in auto mode