bof [cflash-id | booted]
show
Supported on all 7210 SAS platforms as described in this document
This command displays the BOF executed on last system boot or on the specified device.
If no device is specified, the BOF used in the last system boot displays. If the BOF has been modified since the system boot, a message displays.
Specifies the cflash directory name.
cf1: (7210 SAS-D, 7210 SAS-Dxp)
cf1: | uf1: (7210 SAS-K 2F1C2T, 7210 SAS-K 2F6C4T, and 7210 SAS-K 3SFP+ 8C)
Keyword to display the boot option file used to boot the system.
The following output is an example of BOF information, and Table: Output fields: BOF describes the output fields.
Sample output*A:ALA# show bof cf1:
===============================================================================
BOF on cf1:
===============================================================================
primary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/bothx.tim
secondary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/bothx.tim
tertiary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/both.tim
primary-dns xxx.xxx.xxx.xxx
dns-domain in.lucent.com
ping 10.135.16.90
#uplinkA Port Settings:
uplinkA-port 1/1/1
uplinkA-address xxx.xxx.x.xx/24
uplinkA-autoneg
uplinkA-duplexfull
uplinkA-speed1000
uplinkA-vlan 0
uplinkA-route xx.xxx.x.x/16 next-hop xxx.xxx.x.x
#uplinkB Port Settings:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkB-autoneg
uplinkB-duplexfull
uplinkB-speed1000
uplinkB-vlan 0
#System Settings:
wait 3
persist on
console-speed 115200
no console-disabled
===============================================================================
*A:ALA#
*A:ALA# show bof booted
===============================================================================
System booted with BOF
===============================================================================
primary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/bothx.tim
secondary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/bothx.tim
tertiary-image ftp://*:*@xx.xxx.xx.xx/./images/auto-boot/solution/both.tim
primary-dns xxx.xxx.xxx.xxx
dns-domain in.lucent.com
ping-address xx.xxx.xx.xx
#uplinkA Port Settings:
uplinkA-port 1/1/1
uplinkA-address xxx.xxx.x.xx/24
uplinkA-autoneg
uplinkA-duplexfull
uplinkA-speed1000
uplinkA-vlan 0
uplinkA-route xx.xxx.x.x/16 next-hop xxx.xxx.x.x
#uplinkB Port Settings:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkA-autoneg
uplinkA-duplexfull
uplinkA-speed1000
uplinkB-vlan 0
#System Settings:
wait 3
persist on
console-speed 115200
no console-disabled
===============================================================================
*A:ALA#
Label |
Description |
---|---|
primary-image |
The primary location of the directory that contains the runtime images of both CPM and IOM |
primary-config |
The primary location of the file that contains the configuration |
primary-dns |
The primary DNS server for resolution of hostnames to IP addresses |
secondary-image |
The secondary location of the directory that contains the runtime images of both CPM and IOM |
secondary-config |
The secondary location of the file that contains the configuration |
secondary-dns |
The secondary DNS server for resolution of hostnames to IP addresses |
tertiary-image |
The tertiary location of the directory that contains the runtime images of both CPM and IOM |
tertiary-config |
The tertiary location of the file that contains the configuration |
tertiary-dns |
The tertiary DNS server for resolution of hostnames to IP addresses |
persist |
on — Persistent indexes between system reboots is enabled off — Persistent indexes between system reboots is disabled |
wait |
The time configured for the boot to pause while waiting for console input |
autonegotiate |
No autonegotiate — Autonegotiate not enabled autonegotiate — Autonegotiate is enabled |
console speed |
The console port baud rate. |
ping-address |
The IPv4 IP address to be used for ping-test after auto-init |
dns domain |
The domain name used when performing DNS address resolution |
uplinkA-address |
Displays the Uplink-A IP address. |
uplinkA-autoneg |
Displays the Auto-negotiation of the management Ethernet port |
uplinkA-duplex |
Displays Full duplex operation |
uplinkA-speed |
Displays the 1000 M/bps operation |
uplinkA-port |
Displays the primary port to be used for auto-boot. |
uplinkA-route |
Displays the static route associated with uplinkA. |
uplinkA-vlan |
Displays the VLAN ID to be used on uplinkA. |
uplinkB-address |
Displays the uplinkB IP address |
uplinkB-autoneg |
Displays the auto-negotiation of the management Ethernet port |
uplinkB-duplex |
Displays the full duplex operation |
uplinkB-speed |
Displays the 1000 M/bps operation |
uplinkB-port |
Displays the secondary port to be used for auto-init |
uplinkB-route |
Displays the static route associated with uplinkB |
uplinkB-vlan |
Displays the VLAN ID to be used on uplinkB |
console-disabled |
Displays the status of serial port console |
boot-messages
show
Supported on all 7210 SAS platforms as described in this document
This command displays boot messages generated during the last system boot.
The following output is an example of boot messages.
Sample output===============================================================================
cf1:/bootlog.txt
===============================================================================
Bootlog started for Version V-0.0.I317
Build V-0.0.I317 bootrom/mpc 7xxx
Built on Tue Jan 6 02:23:14 IST 2016 by panosbld in /panosbld/ws/panos/main
?Attempting to load from file cf1:/boot.tim
Version L-0.0.I312, Fri Jan 2 04:26:32 IST 2016 by panosbld in /panosbld/ws/panos/
main
text:(3002475-->12623392) + data:(550940-->2414128)
Starting at 0xb000000...
Total Memory: 512MB Chassis Type: sas Card Type: badami_7210
TiMOS-L-0.0.I312 boot/mpc NOKIA SAS-D 7210 Copyright (c) 2016 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Fri Jan 2 04:26:32 IST 2016 by panosbld in /panosbld/ws/panos/main
TiMOS BOOT LOADER
Extended checks enabled with overhead of 36B
Time from clock is THU JAN 08 16:04:05 2016 UTC
Switching serial output to sync mode... done
Looking for cf1:/bof.cfg ... OK, reading
Contents of Boot Options File on cf1:
primary-image ftp://*:*@xxx.xxx.xxx.xx/import/panos_nightly_builds/1.0/B1-
12/STU-sultan/both.tim
primary-config cf1:\config.cfg
#uplinkA Port Settings:
uplinkA-port 1/1/13
uplinkA-autoneg
uplinkA-duplexfull
uplinkA-speed1000
uplinkA-address xx.xxx.xx.xxx/24
uplinkA-vlan null
uplinkA-route xx.xxx.x.x/16 next-hop xx.xxx.xx.x
uplinkA-route xxx.xxx.x.x/16 next-hop xx.xxx.xx.x
#uplinkB Port Settings:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkB-autoneg
uplinkB-duplexfull
uplinkB-speed1000
uplinkB-vlan 0
#System Settings:
wait 3
persist off
console-speed 115200
Hit a key within 1 second to change boot parms...
Configuring Network with uplinkA Port Setting.....
Primary config file present at: cf1:\config.cfg
Primary image location: ftp://*:*@xxx.xxx.xxx.xx/import/panos_nightly_builds/1.0/B1-
12/STU-sultan/both.tim
Initializing uplinkA port using IP addr xx.xxx.xx.xxx.
Loading image ftp://*:*@xxx.xxx.xxx.xx/import/panos_nightly_builds/1.0/B1-12/STU-
sultan/both.tim
Version B-1.0.B1-12, Wed Jan 7 00:58:35 IST 2016 by builder in /builder/ws/panos/
main
text:(27022791-->84574868) + data:(1921023-->10720420)
Executing TiMOS image at 0x100000
Total Memory: 512MB Chassis Type: sas Card Type: badami_7210
TiMOS-B-1.0.B1-12 both/mpc NOKIA 7210 Copyright (c) 2016 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Wed Jan 7 00:58:35 IST 2016 by builder in /builder/ws/panos/main
___ ___ ___ ___
/\ \ /\__\ /\ \ /\ \
\:\ \ ___ /::| | /::\ \ /::\ \
\:\ \ /\__\ /:|:| | /:/\:\ \ /:/\ \ \
/::\ \ _\/__/ /:/|:|__|__ /:/ \:\ \ _\:\~\ \ \
/:/\:\__\ /\__\ /:/ |::::\__\ /:/__/ \:\__\ /\ \:\ \ \__\
/:/ \/__/ /:/ / \/__/~~/:/ / \:\ \ /:/ / \:\ \:\ \/__/
/:/ / /:/ / /:/ / \:\ /:/ / \:\ \:\__\
\/__/ \/__/ /:/ / \:\/:/ / \:\/:/ /
/:/ / \::/ / \::/ /
\/__/ \/__/ \/__/
Time from clock is THU JAN 08 16:05:20 2016 UTC
Attempting to exec primary configuration file:
'cf1:\config.cfg' ...
System Configuration
System Security Configuration
Log Configuration
System Security Cpm Hw Filters Configuration
QoS Slope and Queue Policies Configuration
Port Scheduler Policies Configuration
Card Configuration
Port Configuration
Management Router Configuration
Router (Network Side) Configuration
Static Route Configuration
Service Configuration
Router (Service Side) Configuration
Executed 234 lines in 0.1 seconds from file cf1:\config.cfg
INFO: CLI #1008 The SNMP daemon is disabled. To enable SNMP, execute the command 'c
onfig>system>snmp no shutdown'.
TiMOS-B-1.0.B1-12 both/mpc NOKIA SAS-D 7210 Copyright (c) 2016 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Wed Jan 7 00:58:35 IST 2016 by builder in /builder/ws/panos/main
Login: