Before configuring an operational group, ensure that the low-priority-defect allDef option is configured on the MEP so that a fault is raised for all errors or faults detected by the MEP.
Use the following syntax to configure an operational group for a Down MEP configured in an Epipe service on an uplink SAP.
config>service>epipe>sap>eth-cfm>mep mep-id# defect-oper-group name
config>service>epipe>sap>eth-cfm>mep 1# defect-oper-group ‟ccm-track-uplink”
The access port on the 7210 SAS node to which the enterprise CPE is connected must be configured with the corresponding monitor object using the monitor-oper-group command.
Use the following syntax to configure monitoring of an operational group.
config>lag# monitor-oper-group
config>port>ethernet# monitor-oper-group
config>port>ethernet# monitor-oper-group ‟ccm-track-uplink”