Hardware commands

chassis

Syntax

chassis [environment] [power-supply]

Context

show

Platforms

Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode

Description

This command displays general chassis status information.

For a virtual chassis (VC), this command displays information about the entire VC. Hardware information can be displayed for individual CPMs, IMMs, power supplies, and fans.

Default

displays all chassis information

Parameters

environment

Displays chassis environmental status information.

power-supply

Displays chassis power supply status information.

Output

The following output is an example of chassis status information, and Table: Output fields: chassis describes the output fields.

Sample output for a 7210 SAS in standalone-VC mode
A:NS1# show chassis 
===============================================================================
Chassis Information
===============================================================================
  Name                              : NS1
  Type                              : 7210 SAS-VC
  HW Type                           : SAS-S 48F4SFP+
  Location                          : 
  Coordinates                       : 
  CLLI code                         :            
  Number of slots                   : 10
  Number of ports                   : 216
      System LED state              : Red
  Over Temperature state            : OK
  VC Stack name                     : VCmix
  Number of VC Nodes                : 6
  Number of IMM-only Nodes          : 5
  Number of CPM-IMM Nodes           : 1
  VC Chassis MAC address (active)   : ab:cd:ef:ab:cd:ef
  Number of MAC addresses (active)  : 10
  VC Chassis MAC address (config)   : ab:cd:ef:ab:cd:ef
  Number of MAC addresses (config)  : 10
  Temperature                       : 67C
  Current alarm state               : alarm active
  Fan Status                        : Ok
  Power Status                      : Failed(Slots:7)
=============================================================================== 
Table: Output fields: chassis

Label

Description

Name

The system name for the router.

Type

Displays the model number.

Location

The system location for the device.

Coordinates

A user-configurable string that indicates the Global Positioning System (GPS) coordinates for the location of the chassis.

For example:

N 45 58 23, W 34 56 12

N37 37' 00 latitude, W122 22' 00 longitude

N36*39.246' W121*40.121'

CLLI Code

The Common Language Location Identifier (CLLI) that uniquely identifies the geographic location of places and specific functional categories of equipment unique to the telecommunications industry.

Number of slots

The number of slots in this chassis that are available for plug-in cards. The total number includes the IOM slots and the CPM slots.

Number of ports

The total number of ports currently installed in this chassis. This count does not include the Ethernet ports on the CPMs that are used for management access.

Critical LED state

The current state of the Critical LED in this chassis.

Major LED state

The current state of the Major LED in this chassis.

Minor LED state

The current state of the Minor LED in this chassis

Base MAC address

The base chassis Ethernet MAC address

Admin chassis mode

The configured chassis mode

Oper chassis mode

The current chassis mode

Part number

The CPM part number

CLEI code

The code used to identify the router

Serial number

The CPM part number

Not user modifiable

Manufacture date

The chassis manufacture date

Not user modifiable

Manufacturing string

Factory-inputted manufacturing text string

Not user modifiable

Administrative state

Up — The card is administratively up

Down — The card is administratively down

Operational state

Up — The card is operationally up

Down — The card is operationally down

Time of last boot

The date and time the most recent boot occurred

Current alarm state

Displays the alarm conditions for the specific board

Number of fan trays

The total number of fan trays installed in this chassis

Number of fans

The total number of fans installed in this chassis

Operational status

Current status of the fan tray

Fan speed

Half speed — The fans are operating at half speed

Full speed — The fans are operating at full speed

Number of power supplies

The number of power supplies installed in the chassis

Power supply number

The ID for each power supply installed in the chassis

AC power

Within range — AC voltage is within range

Out of range — AC voltage is out of range

DC power

Within range — DC voltage is within range

Out of range — DC voltage is out of range

Over temp

Within range — The current temperature is within the acceptable range

Out of range — The current temperature is above the acceptable range

Status

Up — The specified power supply is up

Down — The specified power supply is down

card

Syntax

card state

card [slot-number]

card [slot-number] [detail]

card [slot-number] active-resource-profile

card [slot-number] fabric-port-status

Context

show

Platforms

Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode

Description

Note:

The card [slot-number] active-resource-profile and card [slot-number] fabric-port-status commands are supported only on the 7210 SAS-R6 and 7210 SAS-R12.

This command displays card information.

If no command line parameters are specified, a card summary for all cards is displayed.

For a 7210 SAS-Sx 1/10GE or 7210 SAS-S 1/10GE configured for standalone-vc, this command shows a summary status of the nodes in the virtual chassis (VC) when no optional command parameters have been specified; see Sample output — show card: 7210 SAS virtual chassis (VC).

IMM-only nodes that are preprovisioned show as provisioned but not equipped.

When a slot number is specified along with the detail keyword, this command displays more information about a specific node in a VC; see Sample output — show card (detail): 7210 SAS virtual chassis (VC).

VC-Stack information appears only when the node chassis-role parameter is configured as standalone-vc.

Parameters

slot-number

Displays information for the specified card slot.

Values

1 to 12, A, B

detail

Displays detailed card information.

state

Displays provisioned and equipped card and MDA information.

active-resource-profile

Displays the active resource profile currently in use by the system. This keyword is supported only on the 7210 SAS-R6 and 7210 SAS-R12.

fabric-port-status

Displays the status of the fabric port. This keyword can be used only with slot A or B. This keyword is supported only on the 7210 SAS-R6 and 7210 SAS-R12.

Output

The following outputs are examples of card information, and the corresponding tables describe the output fields.

Sample output — show card
*A:MTU-A# show card 
===============================================================================
Card Summary
===============================================================================
Slot      Provisioned         Equipped            Admin      Operational       
          Card-type           Card-type           State      State             
-------------------------------------------------------------------------------
1         iom-24g             iom-24g             up         up                
A         sfm-24g             sfm-24g             up         up/active         
===============================================================================
*A:MTU-A# 

*A:ces-A# show card 

===============================================================================
Card Summary
===============================================================================
Slot      Provisioned         Equipped            Admin      Operational       
          Card-type           Card-type           State      State             
-------------------------------------------------------------------------------
1         iom-sas             iom-sas             up         up                
A         sfm-sas             sfm-sas             up         up/active         
===============================================================================
Table: Output fields: show card

Label

Description

Slot

Displays the slot number of the card in the chassis

Provisioned Card-type

Displays the card type that is configured for the slot

Equipped Card-type

Displays the card type that is actually populated in the slot

Admin State

Up — the card is administratively up

Down — the card is administratively down

Operational State

Up — the card is operationally up

Down — the card is operationally down

Sample output — show card: 7210 SAS-R6, IMM-SAS-R and IMM-SAS-R-b

*A:dut-b>show# card

===============================================================================
Card Summary
===============================================================================
Slot   Provisioned Type                            Admin Operational   Comments
           Equipped Type (if different)            State State
-------------------------------------------------------------------------------
1      imm-sas-b-10sfp-1sfp+                       up    up
2      imm-sas-b-11csfp                            up    up
3      imm-sas-b-11csfp                            up    up
4      imm-sas-b-11csfp                            up    up
5      imm-sas-b-10sfp-1sfp+                       up    up
6      imm-sas-b-10sfp-1sfp+                       up    up
A      cpm-sf-b-sas-R6                             up    up/active
B      cpm-sf-b-sas-R6                             up    up/standby
===============================================================================
*A:dut-b>show#
Sample output — show card: 7210 SAS virtual chassis (VC)
*A:sas-vc-dutb>show# card
=============================================================================
Card Summary
=============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
1         sas-s-24t-4sfpp                          up    up            CPMA-IMM
2         sas-s-24sfp-4sfpp                        up    up            CPMB-IMM
3         sas-sx-24sfp-4sfpp                       up    up            IMM-ONLY
A         sfm-sas                                  up    up/active     
B         sfm-sas                                  up    up/standby
=============================================================================
*A:sas-vc-dutb>show#
Sample output — show card (detail): 7210 SAS virtual chassis (VC)
A:NS1653T0051# show card  1  detail
=============================================================================
Card 1
=============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State
-----------------------------------------------------------------------------
1         sas-s-48t-4sfpp                          up    up
IOM Card Specific Data
    Clock source                  : none
    Named Pool Mode               : Disabled
    Available MDA slots           : 1
    Installed MDAs                : 1
    System Resource Profile       : 1
Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE10535AARA01
    CLEI code                     :
    Serial number                 : NS1653T0051
    Manufacture date              : 01032017
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number :
    Administrative state          : up
    Operational state             : up
    Temperature                   : 63C
    Temperature threshold         : 85C
    Software boot (rom) version   : X-9.0.S249 on Thu Mar 23 03:33:30 IST 2017
                                    by builder
    Software version              : TiMOS-B-0.0.private both/hops Nokia SAS-S
                                    48T4SFP+ 7210 Copyright (c) 2000-2017
                                    Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Tue Oct 24 16:40:11 IST 2017 by
                                    sch001 in /home/sch001/ws/GitWs/00/panos/
                                    main
    Time of last boot             : 2000/01/01 00:52:34
    Current alarm state           : alarm cleared
    Base MAC address              : d0:99:d5:92:70:41
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 2,048 MB
-----------------------------------------------------------------------------
VC-Stack Information                  
    VC Stack Name                 : VCpoeMix
    VC Stack Node Type            : imm-only
    VC Stack Node Slot Number     : 1
    VC Stack Node Description     : 
    VC Stack Port#1 Oper State    : Up
    VC Stack Port#2 Oper State    : Down
    Neighbor to VC Stack Port#1   : 6
    Neighbor to VC Stack Port#2   : None
-----------------------------------------------------------------------------
Environment Information
  Number of fans                    : 3
    Speed                           : half speed
    Status                          : up or failed (Fan #1 failed)
-----------------------------------------------------------------------------
Power Supply Information
  Number of power supplies          : 2
  Power supply number               : 1
    Configured power supply type    : dc
    Status                          : failed
    DC power                        : out of range
  Power supply number               : 2
    Configured power supply type    : ac single
    Status                          : up
    DC power                        : within range
=============================================================================
A:NS1653T0051#
Sample output — show card: 7210 SAS in standalone VC mode
A:NS1# show card 
===============================================================================
Card Summary
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
1         sas-s-24sfp-4sfpp                        up    up            IMM-ONLY
2         sas-s-48sfp-4sfpp                        up    up            CPMA-IMM
3         sas-s-24t-4sfpp                          up    up            IMM-ONLY
4         sas-s-24t-4sfpp                          up    provisioned   Unknown
              (not equipped)                       
5         sas-sx-48sfp-4sfpp                       up    up            IMM-ONLY
6         sas-sx-24t-4sfpp                         up    up            IMM-ONLY
7         sas-s-24t-4sfpp                          up    up            IMM-ONLY
A         sfm-sas                                  up    up/active     
B         sfm-sas                                  up    down/standby  Unknown
              (not equipped)                       
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS in standalone VC mode, power supply
A:NS1# show card 1 power-supply 
===============================================================================
Power Supply Information - Card 1
===============================================================================
Power Supply Information
  Number of power supplies          : 2
  
  Power supply number               : 1
    Configured power supply type    : ac single
    Status                          : up
    AC power                        : within range
  
  Power supply number               : 2
    Configured power supply type    : dc
    Status                          : up
    DC power                        : within range
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS in standalone VC mode, environment
A:NS1# show card 2 environment 
===============================================================================
Environment Information - Card 2
===============================================================================
Environment Information
  Number of fan trays               : 1
  Number of fans                    : 2
  
  Fan tray number                   : 1
    Speed                           : half speed
    Status                          : up
===============================================================================
A:NS1#
Sample output — show card (detail): 7210 SAS in standalone VC mode
A:NS1# show card 1 detail 
===============================================================================
Card 1
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
1         sas-s-24sfp-4sfpp                        up    up            IMM-ONLY
IOM Card Specific Data
    Clock source                  : none
    Named Pool Mode               : Disabled
    Available MDA slots           : 1
    Installed MDAs                : 1
    System Resource Profile       : 1
Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE10000AAAA01
    CLEI code                     : INM0000ERA
    Serial number                 : NS0000A0000
    Manufacture date              : 07182017
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number :   
    Administrative state          : up
    Operational state             : up
    Temperature                   : 58C
    Temperature threshold         : 85C
    Software boot (rom) version   : X-10.0.R5 on Fri Jun 29 12:20:22 IST 2018
                                    by sasbuild
    CPU Control FPGA version      : 0x8
    Software version              : TiMOS-B-10.0.R5 both/hops Nokia SAS-S
                                    24F4SFP+ 7210 Copyright (c) 2000-2018
                                    Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Fri Jun 29 12:21:09 IST 2018 by
                                    sasbuild in /test/sasbuild/
    Time of last boot             : 2018/07/10 16:04:03
    Current alarm state           : alarm cleared
    Base MAC address              : d0:99:d5:9c:98:41
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 2,048 MB
-------------------------------------------------------------------------------
                                      
VC-Stack Information
    VC Stack Name                 : VCmix
    VC Stack Node Type            : imm-only
    VC Stack Node Slot Number     : 1
    VC Stack Node Description     : 
    VC Stack Port#1 Oper State    : Up
    VC Stack Port#2 Oper State    : Up
    Neighbor to VC Stack Port#1   : 3
    Neighbor to VC Stack Port#2   : 6
-------------------------------------------------------------------------------
Power Supply Information
    Number of power supplies      : 2
    
    Power supply number           : 1
        Configured power supply t*: ac single
        Status                    : up
        AC power                  : within range
    
    Power supply number           : 2
        Configured power supply t*: dc
        Status                    : up
        DC power                  : within range
-------------------------------------------------------------------------------
Environment Information
    Number of fan trays           : 1
    Number of fans                : 2
    
    Fan tray number               : 1
        Speed                     : half speed
        Status                    : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1#             


A:NS1#  show card 7 detail 
===============================================================================
Card 7
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
7         sas-s-24t-4sfpp                          up    up            IMM-ONLY
IOM Card Specific Data
    Clock source                  : none
    Named Pool Mode               : Disabled
    Available MDA slots           : 1
    Installed MDAs                : 1
    System Resource Profile       : 1
Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE10000AAAA01
    CLEI code                     : INM3A00AAA
    Serial number                 : NS1000A0000
    Manufacture date              : 06052017
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number :   
    Administrative state          : up
    Operational state             : up
    Temperature                   : 65C
    Temperature threshold         : 85C
    Software boot (rom) version   : X-10.0.R5 on Fri Jun 29 12:20:22 IST 2018
                                    by sasbuild
    CPU Control FPGA version      : 0x8
    Software version              : TiMOS-B-10.0.R5 both/hops Nokia SAS-S
                                    24T4SFP+ 7210 Copyright (c) 2000-2018
                                    Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Fri Jun 29 12:21:09 IST 2018 by
                                    sasbuild in /test/sasbuild/
    Time of last boot             : 2018/07/10 16:11:06
    Current alarm state           : alarm cleared
    Base MAC address              : d0:99:d5:9a:64:41
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 2,048 MB
-------------------------------------------------------------------------------
                                      
VC-Stack Information
    VC Stack Name                 : VCmix
    VC Stack Node Type            : imm-only
    VC Stack Node Slot Number     : 7
    VC Stack Node Description     : 
    VC Stack Port#1 Oper State    : Up
    VC Stack Port#2 Oper State    : Down
    Neighbor to VC Stack Port#1   : 6
    Neighbor to VC Stack Port#2   : None
-------------------------------------------------------------------------------
Power Supply Information
    Number of power supplies      : 2
    
    Power supply number           : 1
        Defaulted power supply ty*: ac single
        Status                    : failed
        AC power                  : out of range
    
    Power supply number           : 2
        Defaulted power supply ty*: dc
        Status                    : up
        DC power                  : within range
-------------------------------------------------------------------------------
Environment Information
    Number of fan trays           : 1
    Number of fans                : 2
    
    Fan tray number               : 1
        Speed                     : half speed
        Status                    : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS-R12, IMM-SAS-R-b
*A:A6144909484>show# card

===============================================================================
Card Summary
===============================================================================
Slot   Provisioned Type                            Admin Operational   Comments
           Equipped Type (if different)            State State
-------------------------------------------------------------------------------
8      (not provisioned)                           up    unprovisioned
           imm-sas-b-4sfp+
A      cpm-sf-sas-R12                              up    up/active
B      cpm-sf-sas-R12                              up    up/standby
===============================================================================
*A:A6144909484>show#
Sample output — show card: 7210 SAS-Sx 10/100GE
*A:7210SAS>show# card

===============================================================================
Card Summary
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State
-------------------------------------------------------------------------------
1         iom-sas                                  up    up
A         sfm-sas                                  up    up/active
===============================================================================
*A:7210SAS>show#
Sample output — show card State
*A:MTU-A# show card state 
===============================================================================
Card State
===============================================================================
Slot/  Provisioned      Equipped         Admin Operational   Num   Num Comments
Id     Type             Type             State State         Ports MDA         
-------------------------------------------------------------------------------
1      iom-24g          iom-24g          up    up                  2           
1/1    m24-100fx-1gb-s* m24-100fx-1gb-s* up    up            24                
A      sfm-24g          sfm-24g          up    up                      Active  
===============================================================================
* indicates that the corresponding row element may have been truncated.
Table: Output fields: card state

Label

Description

Slot/MDA

Displays the slot number of the card in the chassis

Provisioned Type

Displays the card type that is configured for the slot

Equipped Type

Displays the card type that is actually populated in the slot

Admin State

Up — the card is administratively up

Down — the card is administratively down

Operational State

Up — the card is operationally up

provisioned — there is no card in the slot but it is preconfigured

Num Ports

Displays the number of ports available on the MDA

Num MDA

Displays the number of MDAs installed

Comments

Indicates whether the SF/CPM is active or standby

Sample output — show card (detail)
*A:SAS# show card detail 
===============================================================================
Card 1
===============================================================================
Slot      Provisioned         Equipped            Admin      Operational       
          Card-type           Card-type           State      State             
-------------------------------------------------------------------------------
1         iom-24g             iom-24g             up         up                


IOM Card Specific Data
    Clock source                  : none                                       
    Available MDA slots           : 2                                          
    Installed MDAs                : 1                                          

Hardware Data
    Part number                   :                                            
    CLEI code                     :                                            
    Serial number                 : MTUSN107210                                
    Manufacture date              :                                            
    Manufacturing string          :                                            
    Manufacturing deviations      :                                            
    Administrative state          : up                                         
    Operational state             : up                                         
    Temperature                   : 40C                                        
    Temperature threshold         : 50C                                        
    Software boot (rom) version   : 7                                          
    Software version              : TiMOS-B-1.1.S29 both/mpc NOKIA SAS 721*  
    Time of last boot             : 2001/06/27 11:15:07                        
    Current alarm state           : alarm cleared                              
    Base MAC address              : 00:11:00:22:bc:11                          
    Memory capacity               : 1,024 MB                                   
===============================================================================
*A:SAS# 
*A:SAS# show card A detail 
===============================================================================
Card A
===============================================================================
Slot      Provisioned         Equipped            Admin      Operational       
          Card-type           Card-type           State      State             
-------------------------------------------------------------------------------
A         sfm-24g             sfm-24g             up         up/active         


BOF last modified                 : N/A                                        
Config file version               : WED JUN 27 11:12:21 2008 UTC               
Config file last modified         : 2008/06/27 11:42:06                        
Config file last saved            : N/A                                        
M/S clocking ref state            : primary                                    

Flash - cf1:
    Administrative State          : up                                         
    Operational state             : up                                         
    Serial number                 : serial-1                                   
    Firmware revision             : v1.0                                       
    Model number                  : Flash 1                                    
    Size                          : 110,984 KB                                 
    Free space                    : 103,264 KB                                 

Hardware Data
    Part number                   :                                            
    CLEI code                     :                                            
    Serial number                 : MTUSN107210                                
    Manufacture date              :                                            
    Manufacturing string          :                                            
    Manufacturing deviations      :                                            
    Administrative state          : up                                         
    Operational state             : up                                         
    Temperature                   : 40C                                        
    Temperature threshold         : 50C                                        
    Software boot (rom) version   : 7                                          
    Software version              : TiMOS-B-1.1.S29 both/mpc NOKIA SAS 721*  
    Time of last boot             : 2008/06/27 11:14:43                        
    Current alarm state           : alarm cleared                              
    Base MAC address              : 00:11:00:22:bc:11                          
    Memory capacity               : 1,024 MB                                   
===============================================================================
*A:SAS# 
Sample output — show card (detail): 7210 SAS-R6 and 7210 SAS-R12

A:NS1653C0258# show card detail
===============================================================================
Card 1
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
1         imm-sas-b-16tx                           up    up            
IOM Card Specific Data
    Clock source                  : none
    Named Pool Mode               : Disabled
    Available MDA slots           : 1
    Installed MDAs                : 1
    System Resource Profile       : 1
Hardware Data
    Platform type                 : N/A
    Part number                   : 
    CLEI code                     : 
    Serial number                 : 01144600022
    Manufacture date              : 
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number : 82-0723-01
    Administrative state          : up
    Operational state             : up
    Temperature                   : 36C
    Temperature threshold         : 96C
    Software boot (rom) version   : X-11.0.B1-213 on Mon Feb 3 15:36:59 IST
                                    2020 by sasbuild
    CPU Control FPGA version      : 0x4
    Software version              : TiMOS-I-11.0.B1-213 iom/arc Nokia SAS-R
                                    7210 Copyright (c) 2000-2020 Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Mon Feb 3 15:45:58 IST 2020 by
                                    sasbuild in /home/sasbuild/11.0B1/panos/
                                    main
    Time of last boot             : 2020/02/04 14:32:56
    Current alarm state           : alarm cleared
    Base MAC address              : e4:81:84:24:1a:1d
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 1,024 MB
    Port Status to CPM-A Fabric   : up
    Port Status to CPM-B Fabric   : up
Table: Output fields: card detail

Label

Description

Available MDA slots

Displays the number of MDA slots available on the IOM

Installed MDAs

Displays the number of MDAs installed on the IOM

Part number

Displays the IOM part number

CLEI code

Displays the Common Language Location Identifier (CLLI) code string for the router

Serial number

Displays the serial number

Not user modifiable

Manufacture date

Displays the chassis manufacture date

Not user modifiable

Manufacturing string

Displays a factory-inputted manufacturing text string

Not user modifiable

Manufacturing deviations

Displays a record of changes by manufacturing to the hardware or software, which is outside the normal revision control process

Administrative state

Up — the card is administratively up

Down — the card is administratively down

Operational state

Up — the card is operationally up

Down — the card is operationally down

Temperature

Displays the internal chassis temperature

Temperature threshold

Displays the value above which the internal temperature must rise to indicate that the temperature is critical

Software boot version

Displays the version of the boot image

Software version

Displays the software version number

Time of last boot

Displays the date and time the most recent boot occurred

Current alarm state

Displays the alarm conditions for the specific board

Base MAC address

Displays the base MAC address of the hardware component

Memory Capacity

Displays the memory capacity of the card

Sample output — show card CPM
A:NS1653C0258# show card "A" detail 
===============================================================================
Card A
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
A         cpm-sf-sas-R12                           up    up/active     
BOF last modified                 : N/A
Config file version               : FRI NOV 08 15:09:44 2019 UTC
Config file last modified         : N/A
Config file last saved            : N/A
M/S clocking ref state            : primary
Flash - cf1: 
    Type                          : Flash
    Administrative State          : up
    Operational state             : up
    Serial number                 : AA00000000014324
    Firmware revision             : 1100
    Model number                  : Flash 1
    Size                          : 1,964 MB
    Free space                    : 1,493 MB
Flash - cf2: 
    Type                          : Compact Flash
    Administrative State          : up
    Operational state             : up
    Serial number                 : 000060069995A600005A
    Firmware revision             : 110301a 
    Model number                  : SFCF4096H1BO2TO-I-D1-543-ALU            
    Size                          : 3,904 MB
    Free space                    : 3,795 MB
Flash - uf1: 
    Type                          : USB
    Administrative State          : up
    Operational state             : up
    Serial number                 : 4C530300241020122174
    Firmware revision             : 1.27
    Model number                  : Cruzer Switch   
    Size                          : 7,481 MB
    Free space                    : 7,372 MB
Hardware Data
    Platform type                 : N/A
    Part number                   : 82-0840-01
    CLEI code                     : 
    Serial number                 : 01153100011
    Manufacture date              : 09182015
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number : 
    Administrative state          : up
    Operational state             : up
    Temperature                   : 67C
    Temperature threshold         : 96C
    Software boot (rom) version   : X-11.0.B1-213 on Mon Feb 3 15:43:37 IST
                                    2020 by sasbuild
    CPU Control FPGA version      : 0x7
    Peripheral Control FPGA versi*: 0x3
    Software version              : TiMOS-C-11.0.B1-213 cpm/hops Nokia SAS-R
                                    7210 Copyright (c) 2000-2020 Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Mon Feb 3 15:46:13 IST 2020 by
                                    sasbuild in /home/sasbuild/11.0B1/panos/
                                    main
    Time of last boot             : 2020/02/04 14:29:31
    Current alarm state           : alarm cleared
    Base MAC address              : a4:7b:2c:07:49:87
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 2,048 MB
    System timing oscillator type : OCXO
    Port Status to CPM-A Fabric   : up
    Port Status to CPM-B Fabric   : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1653C0258# show card "B" detail 
===============================================================================
Card B
===============================================================================
Slot      Provisioned Type                         Admin Operational   Comments
              Equipped Type (if different)         State State         
-------------------------------------------------------------------------------
B         cpm-sf-sas-R12                           up    up/standby    
BOF last modified                 : N/A
Config file version               : 
Config file last modified         : N/A
Config file last saved            : N/A
M/S clocking ref state            : secondary
Flash - cf1: 
    Type                          : Flash
    Administrative State          : up
    Operational state             : up
    Serial number                 : AA00000000014325
    Firmware revision             : 1100
    Model number                  : Flash 1
    Size                          : 1,964 MB
    Free space                    : 1,726 MB
Flash - cf2: 
    Type                          : Compact Flash
    Administrative State          : up
    Operational state             : up
    Serial number                 : 000060093464B00000FF
    Firmware revision             : 110301a 
    Model number                  : SFCF32GBH1BO4TO-I-NC-543-ALU            
    Size                          : 31,248 MB
    Free space                    : 31,137 MB
Flash - uf1: 
    Type                          : USB
    Administrative State          : up
    Operational state             : up
    Serial number                 : 4C532000070108113102
    Firmware revision             : 1.26
    Model number                  : Cruzer Blade    
    Size                          : 3,811 MB
    Free space                    : 3,772 MB
Hardware Data
    Platform type                 : N/A
    Part number                   : 
    CLEI code                     : 
    Serial number                 : 
    Manufacture date              : 
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number : 
    Administrative state          : up
    Operational state             : up
    Temperature                   : 88C
    Temperature threshold         : 96C
    Software boot (rom) version   : X-11.0.B1-213 on Mon Feb 3 15:43:37 IST
                                   2020 by sasbuild
    CPU Control FPGA version      : 0x7
    Peripheral Control FPGA versi*: 0x3
    Software version              : TiMOS-C-11.0.B1-213 cpm/hops Nokia SAS-R
                                    7210 Copyright (c) 2000-2020 Nokia.
                                    All rights reserved. All use subject to
                                    applicable license agreements.
                                    Built on Mon Feb 3 15:46:13 IST 2020 by
                                    sasbuild in /home/sasbuild/11.0B1/panos/
                                    main
    Time of last boot             : 2020/02/14 16:03:57
    Current alarm state           : alarm cleared
    Base MAC address              : a4:7b:2c:07:49:9f
    Firmware revision status      : acceptable
    Last bootup reason            : hard boot
    Memory capacity               : 2,048 MB
    System timing oscillator type : OCXO
    Port Status to CPM-A Fabric   : up
    Port Status to CPM-B Fabric   : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1653C0258#
Table: Output fields: card CPM

Label

Description

Slot

Displays the slot of the card in the chassis

Card Provisioned

Displays the SF/CPM type that is configured for the slot

Card Equipped

Displays the SF/CPM type that is actually populated in the slot

Admin State

Up — the SF/CPM is administratively up

Down — the SF/CPM is administratively down

Operational State

Up — the SF/CPM is operationally up

Down — the SF/CPM is operationally down

BOF last modified

Displays the date and time of the most recent BOF modification

Config file version

Displays the configuration file version

Config file last modified

Displays the date and time of the most recent config file modification

Config file last modified

Displays the date and time of the most recent config file modification

Config file last saved

Displays the date and time of the most recent config file save

CPM card status

active — the card is acting as the primary (active) CPM in a redundant system

standby — the card is acting as the standby (secondary) CPM in a redundant system

Administrative state

Up — the CPM is administratively up

Down — the CPM is administratively down

Operational state

Up — the CPM is operationally up

Down — the CPM is operationally down

Serial number

Displays the compact flash part number

Not user modifiable

Firmware revision

Displays the firmware version

Not user modifiable

Model number

Displays the compact flash model number

Not user modifiable

Size

Displays the amount of space available on the compact flash card

Free space

Displays the amount of space remaining on the compact flash card

Part number

Displays the SF/CPM part number

CLEI code

Displays the code used to identify the router

Serial number

Displays the SF/CPM part number

Not user modifiable

Manufacture date

Displays the chassis manufacture date

Not user modifiable

Manufacturing string

Displays the factory-inputted manufacturing text string

Not user modifiable

Administrative state

Up — the card is administratively up

Down — the card is administratively down

Operational state

Up — the card is operationally up

Down — the card is operationally down

Time of last boot

Displays the date and time the most recent boot occurred

Current alarm state

Displays the alarm conditions for the specific board

Status

Displays the current status

Temperature

Displays the internal chassis temperature

Temperature threshold

Displays the value above which the internal temperature must rise to indicate that the temperature is critical

Software boot version

Displays the version of the boot image

Memory capacity

Displays the total amount of memory

Sample output — active resource profile
7210SAS>show# card 1 active-resource-profile

===============================================================================
Active System Resource Profile For Card : 1
===============================================================================
-------------------------------------------------------------------------------
Configured System Resource Profile Policy Id : 1
-------------------------------------------------------------------------------
G8032 Control Sap Tags     : 0-0
-------------------------------------------------------------------------------
Ingress Internal CAM       : 9
-------------------------------------------------------------------------------
Sap Ingress Qos resource   : 3 (def)    Sap  Aggregate Meter (#)   : 2 (def)
-------------------------------------------------------------------------------
IPv4 Resource              : max        Mac  Resource              : max
IPv4-IPv6 Resource         : max        IPv4-Mac Resource          : max

-------------------------------------------------------------------------------
Net Ingress Qos resource   : 2 (def)
-------------------------------------------------------------------------------

-------------------------------------------------------------------------------
Sap Ingress ACL resource   : 2 (def)
-------------------------------------------------------------------------------
IPv4 Resource              : max        Mac  Resource              : max
IPv4-IPv6 128 bit Resource : max        IPv6 64 bit Resource       : max

-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Eth CFM                    : 1 (def)
-------------------------------------------------------------------------------
down-mep                   : 1          up-mep                     : disable
-------------------------------------------------------------------------------
Sap Egress QoS resource    : 1 (def)
-------------------------------------------------------------------------------

-------------------------------------------------------------------------------
Egress Internal CAM        : 0
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Sap Egress ACL resource    : 2 (def)
-------------------------------------------------------------------------------
Mac and IPv4 Resource      : 2          Mac-only Resource          : disable
IPv6 128 bit Resource      : disable    Mac and IPv6 64 bit Resour*: disable

-------------------------------------------------------------------------------
===============================================================================
* indicates that the corresponding row element may have been truncated.
# indicates that the value will take effect only after reboot or clear card.
7210SAS>show#
Table: Output fields: card active resource profile

Label

Description

Active System Resource Profile For Card

Policy ID: The policy ID of the active system resource profile

Configured System Resource Profile Policy ID

Policy ID of the configured system resource profile. This takes affect after a reboot or reset of the card.

G8032 Control Sap Tags

Displays the Control VLANs reserved for use by G8032

Ingress Internal CAM

Resources allocated toward the Ingress internal TCAM pool

Sap Ingress Qos resource

Resources allocated toward SAP ingress classification and SAP ingress policing

SAP Aggregate Meter

Resources allocated toward SAP aggregate meter support

IPv4 Resource

Resources allocated toward SAP ingress IPv4-IPv6 classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide.

IPv4-IPv6 Resource

Resources allocated toward SAP ingress IPv4-IPv6 classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide.

Mac Resource

Resources allocated toward SAP ingress MAC classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide.

IPv4-Mac Resource

Resources allocated toward SAP ingress IPv4 and MAC classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide.

Net Ingress Qos resource

Resources allocated toward Network Ingress Qos classification (both port-based and IP -interface based). See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide.

Sap Ingress ACL resource

Resources allocated toward ingress ACLs (both SAP and network ingress). See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide.

IPv4-IPv6 128 bit Resource

Resources allocated toward ingress ACLs using IPv4 or IPv6 (with 128-bit IP addresses) classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide.

IPv6 64 bit Resource

Resources allocated toward ingress ACLs using IPv4 or IPv6 (with 64-bit IP addresses) classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide.

Eth CFM

Resources allocated toward Ethernet CFM (UP MEP, Down MEP, MIPs, and so on)

down-mep

Resources allocated toward ETH-CFM Down MEP

Sap Egress QoS resource

Resources allocated toward SAP Egress queues

Egress Internal CAM

Resources allocated toward egress internal tcam pool

Sap Egress ACL resource

Resources allocated for egress ACLs (SAP and IP interface)

MAC and IPv4 Resource

Resources allocated toward egress ACLs with IPv4 or MAC criteria

Mac-only Resource

Resources allocated toward egress ACLs with MAC criteria

IPv6 128 bit Resource

Resources allocated toward egress ACLs with IPv6 (with 128-bit IP addresses) criteria

MAC and IPv6 64 bit Resource

Resources allocated toward egress ACLs with IPv6 (with 64-bit IP addresses) criteria or MAC criteria

Sample output — fabric port status
A:NS1653C0258# show card "A" fabric-port-status 
===============================================================================
Fabric Connectivity Information
===============================================================================
Slot No   Equipped Type                      Fabric Port State
-------------------------------------------------------------------------------
1         imm-sas-b-16tx                     up
2         imm-sas-b-11csfp                   up
3         imm-sas-b-11csfp                   up
4         imm-sas-b-16tx                     up
5         imm-sas-b-16tx                     up
6         imm-sas-b-4sfp+                    up
7         imm-sas-b-2sfp+                    up
8         imm-sas-b-10sfp-1sfp+              up
9         imm-sas-b-10sfp-1sfp+              up
10        imm-sas-b-2sfp+                    up
11        imm-sas-b-11csfp                   up
12        imm-sas-b-10sfp-1sfp+              up
A         cpm-sf-sas-R12                     up
B         cpm-sf-sas-R12                     up
-------------------------------------------------------------------------------
Entries found: 14
===============================================================================

A:NS1653C0258# show card "B" fabric-port-status 
===============================================================================
Fabric Connectivity Information
===============================================================================
Slot No   Equipped Type                      Fabric Port State
-------------------------------------------------------------------------------
1         imm-sas-b-16tx                     up
2         imm-sas-b-11csfp                   up
3         imm-sas-b-11csfp                   up
4         imm-sas-b-16tx                     up
5         imm-sas-b-16tx                     up
6         imm-sas-b-4sfp+                    up
7         imm-sas-b-2sfp+                    up
8         imm-sas-b-10sfp-1sfp+              up
9         imm-sas-b-10sfp-1sfp+              up
10        imm-sas-b-2sfp+                    up
11        imm-sas-b-11csfp                   up
12        imm-sas-b-10sfp-1sfp+              up
A         cpm-sf-sas-R12                     up
B         cpm-sf-sas-R12                     up
-------------------------------------------------------------------------------
Entries found: 14
===============================================================================
Table: Output fields: card fabric port status

Label

Description

Slot No

Displays the slot number of the card in the chassis

Equipped Type

Displays the card type that is actually populated in the slot

Fabric Port State

Displays the state of the fabric port: up or down

mda

Syntax

mda [slot [/mda]] [detail]

Context

show

Platforms

Supported on all 7210 SAS platforms as described in this document.

Description

This command displays MDA information.

Default

a summary output of all MDAs is displayed in table format

Parameters

slot

Specifies the slot number for which to display MDA information.

mda

Specifies the MDA number in the slot for which to display MDA information.

Values

1

detail

Displays detailed MDA information.

Output

The following output is an example of MDA information, and Table: Output Fields: MDA Detailed and Table: Output Fields: MDA describe the output fields.

Sample output —7210 SAS-T
A:SAST>show# mda detail

===============================================================================
MDA 1/1 detail
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
1     1     m12-sfp+10-tx+4-xfp                         up        up


MDA Specific Data
    Maximum port count            : 26
    Number of ports equipped      : 26
    Network ingress queue policy  : default
    Capabilities                  : Ethernet

Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE08117AAAA01
    CLEI code                     :
    Serial number                 : NS1310C2059
    Manufacture date              : 03252013
    Manufacturing string          : (Not Specified)
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number :
    Administrative state          : up
    Operational state             : up
    Temperature                   : 41C
    Temperature threshold         : 68C
        Low Temperature threshold : -20C
    Software version              : N/A
    Time of last boot             : 2015/02/16 08:20:58
    Current alarm state           : alarm cleared
    Base MAC address              : 4c:5f:d2:7c:fa:30
    Firmware version              : N/A
===============================================================================
A:SAST>show#

Table: Output Fields: MDA Detailed

Label

Description

Slot

The chassis slot number

Slot

The MDA slot number

Provisioned Provisioned-type

The provisioned MDA type

Equipped Mda-type

The MDA type that is physically inserted into this slot in this chassis

Admin State

Up — The MDA is administratively up

Down — The MDA is administratively down

Operational State

Up — The MDA is operationally up

Down — The MDA is operationally down

Maximum port count

The maximum number of ports that can be equipped on the MDA card

Number of ports equipped

The number of ports that are actually equipped on the MDA

Transmit timing selected

Indicates the source for the timing used by the MDA

Sync interface timing status

Indicates whether the MDA has qualified one of the timing signals from the CPMs

Transmit timing selected

The transmit timing method which is presently selected and being

used by this MDA

Sync Interface timing status

Indicates the status of the synchronous equipment timing subsystem

Network Ingress Queue Policy

Specifies the network queue policy applied to the MDA to define the queuing structure for this object

Capabilities

Specifies the minimum size of the port that can exist on the MDA.

Part number

The hardware part number.

CLEI code

The code used to identify the MDA.

Serial number

The MDA part number

Not user modifiable

Manufacture date

The MDA manufacture date

Not user modifiable

Manufacturing string

Factory-inputted manufacturing text string

Not user modifiable

Administrative state

Up — The MDA is administratively up.

Down — The MDA is administratively down.

Operational state

Up — The MDA is operationally up.

Down — The MDA is operationally down.

Time of last boot

The date and time the most recent boot occurred.

Current alarm state

Displays the alarm conditions for the specific MDA.

Base MAC address

The base chassis Ethernet MAC address. Special purpose MAC addresses used by the system software are constructed as offsets from this base address.

Sample output — 7210 SAS-Sx/S 1/10GE 48T 4SFP+ variant
*7210SAS>show# mda detail

===============================================================================
MDA 1/1 detail
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
1     1     s48-t4-sfpp                                 up        up


MDA Specific Data
    Maximum port count            : 52
    Number of ports equipped      : 52
    Network ingress queue policy  : default
    Capabilities                  : Ethernet
    Fail On Error                 : Disabled
    Egress XPL error threshold    : 1000
    Egress XPL error window       : 60
    Ingress XPL error threshold   : 1000
    Ingress XPL error window      : 60

Hardware Data
    Platform type                 : N/A
    Part number                   : 1160400046
    CLEI code                     :
    Serial number                 : 01160400046
    Manufacture date              :
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number : 82-0827-01
    Administrative state          : up
    Operational state             : up
    Temperature                   : 59C
    Temperature threshold         : 96C
    Software version              : N/A
    Time of last boot             : 2000/01/19 08:59:27
    Current alarm state           : alarm cleared
    Base MAC address              : a4:7b:2c:c6:69:d5
    Firmware version              : N/A
===============================================================================
*A:hw_sass_duth>show#

Sample output — 7210 SAS-Sx 10/100GE
*A:NS1633T0067>show# mda

===============================================================================
MDA Summary
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
1     1     s64-sfpp+4-cfp                              up        up
===============================================================================
*A:NS1633T0067>show#
*A:NS1633T0067>show# mda detail

===============================================================================
MDA 1/1 detail
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
1     1     s64-sfpp+4-cfp                              up        up


MDA Specific Data
    Maximum port count            : 68
    Number of ports equipped      : 68
    Network ingress queue policy  : default
    Capabilities                  : Ethernet
    Fail On Error                 : Disabled
    Egress XPL error threshold    : 1000
    Egress XPL error window       : 60

Hardware Data
    Platform type                 : N/A
    Part number                   : AABBCCDD-11
    CLEI code                     :
    Serial number                 : NS1633T0067
    Manufacture date              :
    Manufacturing deviations      : (Not Specified)
    Manufacturing assembly number :
    Administrative state          : up
    Operational state             : up
    Temperature                   : 29C
    Temperature threshold         : 85C
    Software boot (rom) version   : (Not Specified)
    Software version              : (Not Specified)
    Time of last boot             : 2000/01/01 00:33:20
    Current alarm state           : alarm cleared
    Base MAC address              : d0:99:d5:8f:5e:43
    Firmware version              : N/A
===============================================================================
*A:NS1633T0067>show#
Table: Output Fields: MDA

Label

Description

Slot

The chassis slot number

MDA

The MDA slot number

Provisioned MDA-type

The MDA type provisioned

Equipped MDA-type

The MDA type actually installed

Admin State

Up — Administratively up

Down — Administratively down

Ops State

Up — Operationally up

Down — Operationally down

Sample output — 7210 SAS-R6 and 7210 SAS-R12
A:dut-a>show# mda detail

===============================================================================
MDA 1/1 detail
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
1     1     imm-sas-10sfp+1xfp                          up        up


MDA Specific Data
    Maximum port count            : 11
    Number of ports equipped      : 11
    Network ingress queue policy  : default
    Capabilities                  : Ethernet

Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE05029AA
    CLEI code                     : Sim CLEI
    Serial number                 : mda-1
    Manufacture date              : 01012003
    Manufacturing string          : Sim MfgString mda-1
    Manufacturing deviations      : Sim MfgDeviation mda-1
    Manufacturing assembly number : 01-2345-67
    Administrative state          : up
    Operational state             : up
    Temperature                   : -128C
    Temperature threshold         : 74C
    Software version              : N/A
    Time of last boot             : 2015/01/30 07:37:12
    Current alarm state           : alarm cleared
    Base MAC address              : 20:89:01:01:00:01
    Firmware version              : N/A

===============================================================================
MDA 2/1 detail
===============================================================================
Slot  Mda   Provisioned Type                            Admin     Operational
                Equipped Type (if different)            State     State
-------------------------------------------------------------------------------
2     1     imm-sas-10sfp+1xfp                          up        up


MDA Specific Data
    Maximum port count            : 11
    Number of ports equipped      : 11
    Network ingress queue policy  : default
    Capabilities                  : Ethernet

Hardware Data
    Platform type                 : N/A
    Part number                   : 3HE05029AA
    CLEI code                     : Sim CLEI
    Serial number                 : mda-1
    Manufacture date              : 01012003
    Manufacturing string          : Sim MfgString mda-1
    Manufacturing deviations      : Sim MfgDeviation mda-1
    Manufacturing assembly number : 01-2345-67
    Administrative state          : up
    Operational state             : up
    Temperature                   : -128C
    Temperature threshold         : 74C
    Software version              : N/A
    Time of last boot             : 2015/01/30 07:37:12
    Current alarm state           : alarm cleared
    Base MAC address              : 20:8a:02:01:00:01
    Firmware version              : N/A
===============================================================================
A:dut-a>show#

pools

Syntax

pools mda-id [/port] [access-app pool-name]

pools mda-id [/port] [network-app pool-name]

Context

show

Platforms

Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode

Description

This command displays pool information.

Parameters

mda-id[/port]

Displays the pool information of the specified MDA.

access-app pool-name

Displays the pool information of the specified QoS policy.

Values

access-ingress, access-egress

network-app pool-name

Displays the pool information of the specified QoS policy.

Values

network-egress

Output

The following output is an example of pool information, and Table: Output fields: pool describes the output fields.

Sample output — 7210 SAS-Mxp
A:Dut-A# show pools 1/1/1 network-egress

===============================================================================
Pool Information
===============================================================================
Port                 : 1/1/1
Application          : System

MMU Configured CBS   : 28728 KB


-------------------------------------------------------------------------------
ID                         FC-MAPS/      CBS (B)     Depth  A.CIR     A.PIR
                           Queue         MBS (B)            O.CIR     O.PIR
-------------------------------------------------------------------------------
Sap Egress Queues:

No Match Found
Network/Access Queues:

1/1/1                           be       131328    0        0         1000000
                                         262656             0         1000448
1/1/1                           l2       131328    0        100000    1000000
                                         262656             100032    1000448
1/1/1                           af       131328    0        100000    1000000
                                         262656             100032    1000448
1/1/1                           l1       131328    0        100000    1000000
                                         262656             100032    1000448
1/1/1                           h2       131328    0        200000    1000000
                                         262656             200064    1000448
1/1/1                           ef       131328    0        200000    1000000
                                         262656             200064    1000448
1/1/1                           h1       131328    0        50000     1000000
                                         262656             50016     1000448
1/1/1                           nc       131328    0        50000     1000000
                                         262656             50016     1000448
=======================================================================

Sample output — 7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
*A:7210SAS>show# pools 1/1/1 access-egress
===============================================================================
Pool Information
===============================================================================
Port                 : 1/1/1
Application          : System

MMU Configured CBS   : 20382 KB


-------------------------------------------------------------------------------
ID                         FC-MAPS/      CBS (B)     Depth  A.CIR     A.PIR
                           Queue         MBS (B)            O.CIR     O.PIR
-------------------------------------------------------------------------------
Sap Egress Queues:

No Match Found
Network/Access Queues:

1/1/1                           be       131328    0        0         1000000
                                         131328             0         1000448
1/1/1                           l2       131328    0        100000    1000000
                                         131328             100032    1000448
1/1/1                           af       131328    0        100000    1000000
                                         131328             100032    1000448
1/1/1                           l1       131328    0        100000    1000000
                                         131328             100032    1000448
1/1/1                           h2       131328    0        200000    1000000
                                         131328             200064    1000448
1/1/1                           ef       131328    0        200000    1000000
                                         131328             200064    1000448
1/1/1                           h1       131328    0        50000     1000000
                                         131328             50016     1000448
1/1/1                           nc       131328    0        50000     1000000
                                         131328             50016     1000448
===============================================================================
*A:7210SAS>show#

Table: Output fields: pool

Label

Description

Type

Specifies the pool type

ID

Specifies the card/mda or card/MDA/port designation

Application/Type

Specifies the nature of usage the pool would be used for. The pools could be used for access or network traffic at either ingress or egress

Pool Name

Specifies the name of the pool being used

Resv CBS

Specifies the percentage of pool size reserved for CBS

Utilization

Specifies the type of the slope policy

State

The administrative status of the port

Start-AvgThreshold

Specifies the percentage of the buffer used after which the drop probability starts to rise above 0

Max-Avg

Specifies the percentage of the buffer used after which the drop probability is 100 percent. This implies that all packets beyond this point will be dropped

Time Avg Factor

Specifies the time average factor the weighting between the previous shared buffer average utilization result and the new shared buffer utilization in determining the new shared buffer average utilization

Actual ResvCBS

Specifies the actual percentage of pool size reserved for CBS

Admin ResvCBS

Specifies the percentage of pool size reserved for CBS

PoolSize

Specifies the size in percentage of buffer space. The value '-1' implies that the pool size should be computed as per fair weighting between all other pools.

Pool Total

Displays the total pool size

Pool Shared

Displays the amount of the pool which is shared.

Pool Resv

Specifies the percentage of reserved pool size.

Pool Total In Use

Displays the total amount of the pool which is in use.

Pool Shared In Use

Displays the amount of the shared pools that is in use.

MMU Configured CBS