chassis [environment] [power-supply]
show
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode
This command displays general chassis status information.
For a virtual chassis (VC), this command displays information about the entire VC. Hardware information can be displayed for individual CPMs, IMMs, power supplies, and fans.
displays all chassis information
Displays chassis environmental status information.
Displays chassis power supply status information.
The following output is an example of chassis status information, and Table: Output fields: chassis describes the output fields.
Sample output for a 7210 SAS in standalone-VC modeA:NS1# show chassis
===============================================================================
Chassis Information
===============================================================================
Name : NS1
Type : 7210 SAS-VC
HW Type : SAS-S 48F4SFP+
Location :
Coordinates :
CLLI code :
Number of slots : 10
Number of ports : 216
System LED state : Red
Over Temperature state : OK
VC Stack name : VCmix
Number of VC Nodes : 6
Number of IMM-only Nodes : 5
Number of CPM-IMM Nodes : 1
VC Chassis MAC address (active) : ab:cd:ef:ab:cd:ef
Number of MAC addresses (active) : 10
VC Chassis MAC address (config) : ab:cd:ef:ab:cd:ef
Number of MAC addresses (config) : 10
Temperature : 67C
Current alarm state : alarm active
Fan Status : Ok
Power Status : Failed(Slots:7)
===============================================================================
Label |
Description |
---|---|
Name |
The system name for the router. |
Type |
Displays the model number. |
Location |
The system location for the device. |
Coordinates |
A user-configurable string that indicates the Global Positioning System (GPS) coordinates for the location of the chassis. For example: N 45 58 23, W 34 56 12 N37 37' 00 latitude, W122 22' 00 longitude N36*39.246' W121*40.121' |
CLLI Code |
The Common Language Location Identifier (CLLI) that uniquely identifies the geographic location of places and specific functional categories of equipment unique to the telecommunications industry. |
Number of slots |
The number of slots in this chassis that are available for plug-in cards. The total number includes the IOM slots and the CPM slots. |
Number of ports |
The total number of ports currently installed in this chassis. This count does not include the Ethernet ports on the CPMs that are used for management access. |
Critical LED state |
The current state of the Critical LED in this chassis. |
Major LED state |
The current state of the Major LED in this chassis. |
Minor LED state |
The current state of the Minor LED in this chassis |
Base MAC address |
The base chassis Ethernet MAC address |
Admin chassis mode |
The configured chassis mode |
Oper chassis mode |
The current chassis mode |
Part number |
The CPM part number |
CLEI code |
The code used to identify the router |
Serial number |
The CPM part number Not user modifiable |
Manufacture date |
The chassis manufacture date Not user modifiable |
Manufacturing string |
Factory-inputted manufacturing text string Not user modifiable |
Administrative state |
Up — The card is administratively up Down — The card is administratively down |
Operational state |
Up — The card is operationally up |
Down — The card is operationally down |
|
Time of last boot |
The date and time the most recent boot occurred |
Current alarm state |
Displays the alarm conditions for the specific board |
Number of fan trays |
The total number of fan trays installed in this chassis |
Number of fans |
The total number of fans installed in this chassis |
Operational status |
Current status of the fan tray |
Fan speed |
Half speed — The fans are operating at half speed |
Full speed — The fans are operating at full speed |
|
Number of power supplies |
The number of power supplies installed in the chassis |
Power supply number |
The ID for each power supply installed in the chassis |
AC power |
Within range — AC voltage is within range |
Out of range — AC voltage is out of range |
|
DC power |
Within range — DC voltage is within range |
Out of range — DC voltage is out of range |
|
Over temp |
Within range — The current temperature is within the acceptable range |
Out of range — The current temperature is above the acceptable range |
|
Status |
Up — The specified power supply is up |
Down — The specified power supply is down |
card state
card [slot-number]
card [slot-number] [detail]
card [slot-number] active-resource-profile
card [slot-number] fabric-port-status
show
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode
The card [slot-number] active-resource-profile and card [slot-number] fabric-port-status commands are supported only on the 7210 SAS-R6 and 7210 SAS-R12.
This command displays card information.
If no command line parameters are specified, a card summary for all cards is displayed.
For a 7210 SAS-Sx 1/10GE or 7210 SAS-S 1/10GE configured for standalone-vc, this command shows a summary status of the nodes in the virtual chassis (VC) when no optional command parameters have been specified; see Sample output — show card: 7210 SAS virtual chassis (VC).
IMM-only nodes that are preprovisioned show as provisioned but not equipped.
When a slot number is specified along with the detail keyword, this command displays more information about a specific node in a VC; see Sample output — show card (detail): 7210 SAS virtual chassis (VC).
VC-Stack information appears only when the node chassis-role parameter is configured as standalone-vc.
Displays information for the specified card slot.
Displays detailed card information.
Displays provisioned and equipped card and MDA information.
Displays the active resource profile currently in use by the system. This keyword is supported only on the 7210 SAS-R6 and 7210 SAS-R12.
Displays the status of the fabric port. This keyword can be used only with slot A or B. This keyword is supported only on the 7210 SAS-R6 and 7210 SAS-R12.
The following outputs are examples of card information, and the corresponding tables describe the output fields.
Sample output — show card: 7210 SAS-R6, IMM-SAS-R and IMM-SAS-R-b
Sample output — show card (detail): 7210 SAS virtual chassis (VC), Table: Output fields: card detail
Sample output — show card: 7210 SAS in standalone VC mode, power supply
Sample output — show card: 7210 SAS in standalone VC mode, environment
Sample output — show card (detail): 7210 SAS in standalone VC mode
Sample output — show card (detail): 7210 SAS-R6 and 7210 SAS-R12
Sample output — show card State, Table: Output fields: card state
Sample output — show card CPM, Table: Output fields: card CPM
Sample output — active resource profile, Table: Output fields: card active resource profile
Sample output — fabric port status, Table: Output fields: card fabric port status
*A:MTU-A# show card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
1 iom-24g iom-24g up up
A sfm-24g sfm-24g up up/active
===============================================================================
*A:MTU-A#
*A:ces-A# show card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
1 iom-sas iom-sas up up
A sfm-sas sfm-sas up up/active
===============================================================================
Label |
Description |
---|---|
Slot |
Displays the slot number of the card in the chassis |
Provisioned Card-type |
Displays the card type that is configured for the slot |
Equipped Card-type |
Displays the card type that is actually populated in the slot |
Admin State |
Up — the card is administratively up Down — the card is administratively down |
Operational State |
Up — the card is operationally up Down — the card is operationally down |
*A:dut-b>show# card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 imm-sas-b-10sfp-1sfp+ up up
2 imm-sas-b-11csfp up up
3 imm-sas-b-11csfp up up
4 imm-sas-b-11csfp up up
5 imm-sas-b-10sfp-1sfp+ up up
6 imm-sas-b-10sfp-1sfp+ up up
A cpm-sf-b-sas-R6 up up/active
B cpm-sf-b-sas-R6 up up/standby
===============================================================================
*A:dut-b>show#
Sample output — show card: 7210 SAS virtual chassis (VC)
*A:sas-vc-dutb>show# card
=============================================================================
Card Summary
=============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 sas-s-24t-4sfpp up up CPMA-IMM
2 sas-s-24sfp-4sfpp up up CPMB-IMM
3 sas-sx-24sfp-4sfpp up up IMM-ONLY
A sfm-sas up up/active
B sfm-sas up up/standby
=============================================================================
*A:sas-vc-dutb>show#
Sample output — show card (detail): 7210 SAS virtual chassis (VC)
A:NS1653T0051# show card 1 detail
=============================================================================
Card 1
=============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-----------------------------------------------------------------------------
1 sas-s-48t-4sfpp up up
IOM Card Specific Data
Clock source : none
Named Pool Mode : Disabled
Available MDA slots : 1
Installed MDAs : 1
System Resource Profile : 1
Hardware Data
Platform type : N/A
Part number : 3HE10535AARA01
CLEI code :
Serial number : NS1653T0051
Manufacture date : 01032017
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 63C
Temperature threshold : 85C
Software boot (rom) version : X-9.0.S249 on Thu Mar 23 03:33:30 IST 2017
by builder
Software version : TiMOS-B-0.0.private both/hops Nokia SAS-S
48T4SFP+ 7210 Copyright (c) 2000-2017
Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Tue Oct 24 16:40:11 IST 2017 by
sch001 in /home/sch001/ws/GitWs/00/panos/
main
Time of last boot : 2000/01/01 00:52:34
Current alarm state : alarm cleared
Base MAC address : d0:99:d5:92:70:41
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 2,048 MB
-----------------------------------------------------------------------------
VC-Stack Information
VC Stack Name : VCpoeMix
VC Stack Node Type : imm-only
VC Stack Node Slot Number : 1
VC Stack Node Description :
VC Stack Port#1 Oper State : Up
VC Stack Port#2 Oper State : Down
Neighbor to VC Stack Port#1 : 6
Neighbor to VC Stack Port#2 : None
-----------------------------------------------------------------------------
Environment Information
Number of fans : 3
Speed : half speed
Status : up or failed (Fan #1 failed)
-----------------------------------------------------------------------------
Power Supply Information
Number of power supplies : 2
Power supply number : 1
Configured power supply type : dc
Status : failed
DC power : out of range
Power supply number : 2
Configured power supply type : ac single
Status : up
DC power : within range
=============================================================================
A:NS1653T0051#
Sample output — show card: 7210 SAS in standalone VC mode
A:NS1# show card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 sas-s-24sfp-4sfpp up up IMM-ONLY
2 sas-s-48sfp-4sfpp up up CPMA-IMM
3 sas-s-24t-4sfpp up up IMM-ONLY
4 sas-s-24t-4sfpp up provisioned Unknown
(not equipped)
5 sas-sx-48sfp-4sfpp up up IMM-ONLY
6 sas-sx-24t-4sfpp up up IMM-ONLY
7 sas-s-24t-4sfpp up up IMM-ONLY
A sfm-sas up up/active
B sfm-sas up down/standby Unknown
(not equipped)
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS in standalone VC mode, power supply
A:NS1# show card 1 power-supply
===============================================================================
Power Supply Information - Card 1
===============================================================================
Power Supply Information
Number of power supplies : 2
Power supply number : 1
Configured power supply type : ac single
Status : up
AC power : within range
Power supply number : 2
Configured power supply type : dc
Status : up
DC power : within range
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS in standalone VC mode, environment
A:NS1# show card 2 environment
===============================================================================
Environment Information - Card 2
===============================================================================
Environment Information
Number of fan trays : 1
Number of fans : 2
Fan tray number : 1
Speed : half speed
Status : up
===============================================================================
A:NS1#
Sample output — show card (detail): 7210 SAS in standalone VC mode
A:NS1# show card 1 detail
===============================================================================
Card 1
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 sas-s-24sfp-4sfpp up up IMM-ONLY
IOM Card Specific Data
Clock source : none
Named Pool Mode : Disabled
Available MDA slots : 1
Installed MDAs : 1
System Resource Profile : 1
Hardware Data
Platform type : N/A
Part number : 3HE10000AAAA01
CLEI code : INM0000ERA
Serial number : NS0000A0000
Manufacture date : 07182017
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 58C
Temperature threshold : 85C
Software boot (rom) version : X-10.0.R5 on Fri Jun 29 12:20:22 IST 2018
by sasbuild
CPU Control FPGA version : 0x8
Software version : TiMOS-B-10.0.R5 both/hops Nokia SAS-S
24F4SFP+ 7210 Copyright (c) 2000-2018
Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Fri Jun 29 12:21:09 IST 2018 by
sasbuild in /test/sasbuild/
Time of last boot : 2018/07/10 16:04:03
Current alarm state : alarm cleared
Base MAC address : d0:99:d5:9c:98:41
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 2,048 MB
-------------------------------------------------------------------------------
VC-Stack Information
VC Stack Name : VCmix
VC Stack Node Type : imm-only
VC Stack Node Slot Number : 1
VC Stack Node Description :
VC Stack Port#1 Oper State : Up
VC Stack Port#2 Oper State : Up
Neighbor to VC Stack Port#1 : 3
Neighbor to VC Stack Port#2 : 6
-------------------------------------------------------------------------------
Power Supply Information
Number of power supplies : 2
Power supply number : 1
Configured power supply t*: ac single
Status : up
AC power : within range
Power supply number : 2
Configured power supply t*: dc
Status : up
DC power : within range
-------------------------------------------------------------------------------
Environment Information
Number of fan trays : 1
Number of fans : 2
Fan tray number : 1
Speed : half speed
Status : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1#
A:NS1# show card 7 detail
===============================================================================
Card 7
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
7 sas-s-24t-4sfpp up up IMM-ONLY
IOM Card Specific Data
Clock source : none
Named Pool Mode : Disabled
Available MDA slots : 1
Installed MDAs : 1
System Resource Profile : 1
Hardware Data
Platform type : N/A
Part number : 3HE10000AAAA01
CLEI code : INM3A00AAA
Serial number : NS1000A0000
Manufacture date : 06052017
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 65C
Temperature threshold : 85C
Software boot (rom) version : X-10.0.R5 on Fri Jun 29 12:20:22 IST 2018
by sasbuild
CPU Control FPGA version : 0x8
Software version : TiMOS-B-10.0.R5 both/hops Nokia SAS-S
24T4SFP+ 7210 Copyright (c) 2000-2018
Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Fri Jun 29 12:21:09 IST 2018 by
sasbuild in /test/sasbuild/
Time of last boot : 2018/07/10 16:11:06
Current alarm state : alarm cleared
Base MAC address : d0:99:d5:9a:64:41
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 2,048 MB
-------------------------------------------------------------------------------
VC-Stack Information
VC Stack Name : VCmix
VC Stack Node Type : imm-only
VC Stack Node Slot Number : 7
VC Stack Node Description :
VC Stack Port#1 Oper State : Up
VC Stack Port#2 Oper State : Down
Neighbor to VC Stack Port#1 : 6
Neighbor to VC Stack Port#2 : None
-------------------------------------------------------------------------------
Power Supply Information
Number of power supplies : 2
Power supply number : 1
Defaulted power supply ty*: ac single
Status : failed
AC power : out of range
Power supply number : 2
Defaulted power supply ty*: dc
Status : up
DC power : within range
-------------------------------------------------------------------------------
Environment Information
Number of fan trays : 1
Number of fans : 2
Fan tray number : 1
Speed : half speed
Status : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1#
Sample output — show card: 7210 SAS-R12, IMM-SAS-R-b
*A:A6144909484>show# card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
8 (not provisioned) up unprovisioned
imm-sas-b-4sfp+
A cpm-sf-sas-R12 up up/active
B cpm-sf-sas-R12 up up/standby
===============================================================================
*A:A6144909484>show#
Sample output — show card: 7210 SAS-Sx 10/100GE
*A:7210SAS>show# card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 iom-sas up up
A sfm-sas up up/active
===============================================================================
*A:7210SAS>show#
Sample output — show card State
*A:MTU-A# show card state
===============================================================================
Card State
===============================================================================
Slot/ Provisioned Equipped Admin Operational Num Num Comments
Id Type Type State State Ports MDA
-------------------------------------------------------------------------------
1 iom-24g iom-24g up up 2
1/1 m24-100fx-1gb-s* m24-100fx-1gb-s* up up 24
A sfm-24g sfm-24g up up Active
===============================================================================
* indicates that the corresponding row element may have been truncated.
Label |
Description |
---|---|
Slot/MDA |
Displays the slot number of the card in the chassis |
Provisioned Type |
Displays the card type that is configured for the slot |
Equipped Type |
Displays the card type that is actually populated in the slot |
Admin State |
Up — the card is administratively up |
Down — the card is administratively down |
|
Operational State |
Up — the card is operationally up |
provisioned — there is no card in the slot but it is preconfigured |
|
Num Ports |
Displays the number of ports available on the MDA |
Num MDA |
Displays the number of MDAs installed |
Comments |
Indicates whether the SF/CPM is active or standby |
*A:SAS# show card detail
===============================================================================
Card 1
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
1 iom-24g iom-24g up up
IOM Card Specific Data
Clock source : none
Available MDA slots : 2
Installed MDAs : 1
Hardware Data
Part number :
CLEI code :
Serial number : MTUSN107210
Manufacture date :
Manufacturing string :
Manufacturing deviations :
Administrative state : up
Operational state : up
Temperature : 40C
Temperature threshold : 50C
Software boot (rom) version : 7
Software version : TiMOS-B-1.1.S29 both/mpc NOKIA SAS 721*
Time of last boot : 2001/06/27 11:15:07
Current alarm state : alarm cleared
Base MAC address : 00:11:00:22:bc:11
Memory capacity : 1,024 MB
===============================================================================
*A:SAS#
*A:SAS# show card A detail
===============================================================================
Card A
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
A sfm-24g sfm-24g up up/active
BOF last modified : N/A
Config file version : WED JUN 27 11:12:21 2008 UTC
Config file last modified : 2008/06/27 11:42:06
Config file last saved : N/A
M/S clocking ref state : primary
Flash - cf1:
Administrative State : up
Operational state : up
Serial number : serial-1
Firmware revision : v1.0
Model number : Flash 1
Size : 110,984 KB
Free space : 103,264 KB
Hardware Data
Part number :
CLEI code :
Serial number : MTUSN107210
Manufacture date :
Manufacturing string :
Manufacturing deviations :
Administrative state : up
Operational state : up
Temperature : 40C
Temperature threshold : 50C
Software boot (rom) version : 7
Software version : TiMOS-B-1.1.S29 both/mpc NOKIA SAS 721*
Time of last boot : 2008/06/27 11:14:43
Current alarm state : alarm cleared
Base MAC address : 00:11:00:22:bc:11
Memory capacity : 1,024 MB
===============================================================================
*A:SAS#
Sample output — show card (detail): 7210 SAS-R6 and
7210 SAS-R12
A:NS1653C0258# show card detail
===============================================================================
Card 1
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 imm-sas-b-16tx up up
IOM Card Specific Data
Clock source : none
Named Pool Mode : Disabled
Available MDA slots : 1
Installed MDAs : 1
System Resource Profile : 1
Hardware Data
Platform type : N/A
Part number :
CLEI code :
Serial number : 01144600022
Manufacture date :
Manufacturing deviations : (Not Specified)
Manufacturing assembly number : 82-0723-01
Administrative state : up
Operational state : up
Temperature : 36C
Temperature threshold : 96C
Software boot (rom) version : X-11.0.B1-213 on Mon Feb 3 15:36:59 IST
2020 by sasbuild
CPU Control FPGA version : 0x4
Software version : TiMOS-I-11.0.B1-213 iom/arc Nokia SAS-R
7210 Copyright (c) 2000-2020 Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Mon Feb 3 15:45:58 IST 2020 by
sasbuild in /home/sasbuild/11.0B1/panos/
main
Time of last boot : 2020/02/04 14:32:56
Current alarm state : alarm cleared
Base MAC address : e4:81:84:24:1a:1d
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 1,024 MB
Port Status to CPM-A Fabric : up
Port Status to CPM-B Fabric : up
Label |
Description |
---|---|
Available MDA slots |
Displays the number of MDA slots available on the IOM |
Installed MDAs |
Displays the number of MDAs installed on the IOM |
Part number |
Displays the IOM part number |
CLEI code |
Displays the Common Language Location Identifier (CLLI) code string for the router |
Serial number |
Displays the serial number Not user modifiable |
Manufacture date |
Displays the chassis manufacture date Not user modifiable |
Manufacturing string |
Displays a factory-inputted manufacturing text string Not user modifiable |
Manufacturing deviations |
Displays a record of changes by manufacturing to the hardware or software, which is outside the normal revision control process |
Administrative state |
Up — the card is administratively up |
Down — the card is administratively down |
|
Operational state |
Up — the card is operationally up |
Down — the card is operationally down |
|
Temperature |
Displays the internal chassis temperature |
Temperature threshold |
Displays the value above which the internal temperature must rise to indicate that the temperature is critical |
Software boot version |
Displays the version of the boot image |
Software version |
Displays the software version number |
Time of last boot |
Displays the date and time the most recent boot occurred |
Current alarm state |
Displays the alarm conditions for the specific board |
Base MAC address |
Displays the base MAC address of the hardware component |
Memory Capacity |
Displays the memory capacity of the card |
A:NS1653C0258# show card "A" detail
===============================================================================
Card A
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
A cpm-sf-sas-R12 up up/active
BOF last modified : N/A
Config file version : FRI NOV 08 15:09:44 2019 UTC
Config file last modified : N/A
Config file last saved : N/A
M/S clocking ref state : primary
Flash - cf1:
Type : Flash
Administrative State : up
Operational state : up
Serial number : AA00000000014324
Firmware revision : 1100
Model number : Flash 1
Size : 1,964 MB
Free space : 1,493 MB
Flash - cf2:
Type : Compact Flash
Administrative State : up
Operational state : up
Serial number : 000060069995A600005A
Firmware revision : 110301a
Model number : SFCF4096H1BO2TO-I-D1-543-ALU
Size : 3,904 MB
Free space : 3,795 MB
Flash - uf1:
Type : USB
Administrative State : up
Operational state : up
Serial number : 4C530300241020122174
Firmware revision : 1.27
Model number : Cruzer Switch
Size : 7,481 MB
Free space : 7,372 MB
Hardware Data
Platform type : N/A
Part number : 82-0840-01
CLEI code :
Serial number : 01153100011
Manufacture date : 09182015
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 67C
Temperature threshold : 96C
Software boot (rom) version : X-11.0.B1-213 on Mon Feb 3 15:43:37 IST
2020 by sasbuild
CPU Control FPGA version : 0x7
Peripheral Control FPGA versi*: 0x3
Software version : TiMOS-C-11.0.B1-213 cpm/hops Nokia SAS-R
7210 Copyright (c) 2000-2020 Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Mon Feb 3 15:46:13 IST 2020 by
sasbuild in /home/sasbuild/11.0B1/panos/
main
Time of last boot : 2020/02/04 14:29:31
Current alarm state : alarm cleared
Base MAC address : a4:7b:2c:07:49:87
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 2,048 MB
System timing oscillator type : OCXO
Port Status to CPM-A Fabric : up
Port Status to CPM-B Fabric : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1653C0258# show card "B" detail
===============================================================================
Card B
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
-------------------------------------------------------------------------------
B cpm-sf-sas-R12 up up/standby
BOF last modified : N/A
Config file version :
Config file last modified : N/A
Config file last saved : N/A
M/S clocking ref state : secondary
Flash - cf1:
Type : Flash
Administrative State : up
Operational state : up
Serial number : AA00000000014325
Firmware revision : 1100
Model number : Flash 1
Size : 1,964 MB
Free space : 1,726 MB
Flash - cf2:
Type : Compact Flash
Administrative State : up
Operational state : up
Serial number : 000060093464B00000FF
Firmware revision : 110301a
Model number : SFCF32GBH1BO4TO-I-NC-543-ALU
Size : 31,248 MB
Free space : 31,137 MB
Flash - uf1:
Type : USB
Administrative State : up
Operational state : up
Serial number : 4C532000070108113102
Firmware revision : 1.26
Model number : Cruzer Blade
Size : 3,811 MB
Free space : 3,772 MB
Hardware Data
Platform type : N/A
Part number :
CLEI code :
Serial number :
Manufacture date :
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 88C
Temperature threshold : 96C
Software boot (rom) version : X-11.0.B1-213 on Mon Feb 3 15:43:37 IST
2020 by sasbuild
CPU Control FPGA version : 0x7
Peripheral Control FPGA versi*: 0x3
Software version : TiMOS-C-11.0.B1-213 cpm/hops Nokia SAS-R
7210 Copyright (c) 2000-2020 Nokia.
All rights reserved. All use subject to
applicable license agreements.
Built on Mon Feb 3 15:46:13 IST 2020 by
sasbuild in /home/sasbuild/11.0B1/panos/
main
Time of last boot : 2020/02/14 16:03:57
Current alarm state : alarm cleared
Base MAC address : a4:7b:2c:07:49:9f
Firmware revision status : acceptable
Last bootup reason : hard boot
Memory capacity : 2,048 MB
System timing oscillator type : OCXO
Port Status to CPM-A Fabric : up
Port Status to CPM-B Fabric : up
* indicates that the corresponding row element may have been truncated.
===============================================================================
A:NS1653C0258#
Label |
Description |
---|---|
Slot |
Displays the slot of the card in the chassis |
Card Provisioned |
Displays the SF/CPM type that is configured for the slot |
Card Equipped |
Displays the SF/CPM type that is actually populated in the slot |
Admin State |
Up — the SF/CPM is administratively up |
Down — the SF/CPM is administratively down |
|
Operational State |
Up — the SF/CPM is operationally up |
Down — the SF/CPM is operationally down |
|
BOF last modified |
Displays the date and time of the most recent BOF modification |
Config file version |
Displays the configuration file version |
Config file last modified |
Displays the date and time of the most recent config file modification |
Config file last modified |
Displays the date and time of the most recent config file modification |
Config file last saved |
Displays the date and time of the most recent config file save |
CPM card status |
active — the card is acting as the primary (active) CPM in a redundant system |
standby — the card is acting as the standby (secondary) CPM in a redundant system |
|
Administrative state |
Up — the CPM is administratively up |
Down — the CPM is administratively down |
|
Operational state |
Up — the CPM is operationally up |
Down — the CPM is operationally down |
|
Serial number |
Displays the compact flash part number Not user modifiable |
Firmware revision |
Displays the firmware version Not user modifiable |
Model number |
Displays the compact flash model number Not user modifiable |
Size |
Displays the amount of space available on the compact flash card |
Free space |
Displays the amount of space remaining on the compact flash card |
Part number |
Displays the SF/CPM part number |
CLEI code |
Displays the code used to identify the router |
Serial number |
Displays the SF/CPM part number Not user modifiable |
Manufacture date |
Displays the chassis manufacture date Not user modifiable |
Manufacturing string |
Displays the factory-inputted manufacturing text string Not user modifiable |
Administrative state |
Up — the card is administratively up |
Down — the card is administratively down |
|
Operational state |
Up — the card is operationally up |
Down — the card is operationally down |
|
Time of last boot |
Displays the date and time the most recent boot occurred |
Current alarm state |
Displays the alarm conditions for the specific board |
Status |
Displays the current status |
Temperature |
Displays the internal chassis temperature |
Temperature threshold |
Displays the value above which the internal temperature must rise to indicate that the temperature is critical |
Software boot version |
Displays the version of the boot image |
Memory capacity |
Displays the total amount of memory |
7210SAS>show# card 1 active-resource-profile
===============================================================================
Active System Resource Profile For Card : 1
===============================================================================
-------------------------------------------------------------------------------
Configured System Resource Profile Policy Id : 1
-------------------------------------------------------------------------------
G8032 Control Sap Tags : 0-0
-------------------------------------------------------------------------------
Ingress Internal CAM : 9
-------------------------------------------------------------------------------
Sap Ingress Qos resource : 3 (def) Sap Aggregate Meter (#) : 2 (def)
-------------------------------------------------------------------------------
IPv4 Resource : max Mac Resource : max
IPv4-IPv6 Resource : max IPv4-Mac Resource : max
-------------------------------------------------------------------------------
Net Ingress Qos resource : 2 (def)
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Sap Ingress ACL resource : 2 (def)
-------------------------------------------------------------------------------
IPv4 Resource : max Mac Resource : max
IPv4-IPv6 128 bit Resource : max IPv6 64 bit Resource : max
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Eth CFM : 1 (def)
-------------------------------------------------------------------------------
down-mep : 1 up-mep : disable
-------------------------------------------------------------------------------
Sap Egress QoS resource : 1 (def)
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Egress Internal CAM : 0
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Sap Egress ACL resource : 2 (def)
-------------------------------------------------------------------------------
Mac and IPv4 Resource : 2 Mac-only Resource : disable
IPv6 128 bit Resource : disable Mac and IPv6 64 bit Resour*: disable
-------------------------------------------------------------------------------
===============================================================================
* indicates that the corresponding row element may have been truncated.
# indicates that the value will take effect only after reboot or clear card.
7210SAS>show#
Label |
Description |
---|---|
Active System Resource Profile For Card |
Policy ID: The policy ID of the active system resource profile |
Configured System Resource Profile Policy ID |
Policy ID of the configured system resource profile. This takes affect after a reboot or reset of the card. |
G8032 Control Sap Tags |
Displays the Control VLANs reserved for use by G8032 |
Ingress Internal CAM |
Resources allocated toward the Ingress internal TCAM pool |
Sap Ingress Qos resource |
Resources allocated toward SAP ingress classification and SAP ingress policing |
SAP Aggregate Meter |
Resources allocated toward SAP aggregate meter support |
IPv4 Resource |
Resources allocated toward SAP ingress IPv4-IPv6 classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide. |
IPv4-IPv6 Resource |
Resources allocated toward SAP ingress IPv4-IPv6 classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide. |
Mac Resource |
Resources allocated toward SAP ingress MAC classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide. |
IPv4-Mac Resource |
Resources allocated toward SAP ingress IPv4 and MAC classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide. |
Net Ingress Qos resource |
Resources allocated toward Network Ingress Qos classification (both port-based and IP -interface based). See the 7210 SAS-Mxp, R6, R12, S, Sx, T Quality of Service Guide. |
Sap Ingress ACL resource |
Resources allocated toward ingress ACLs (both SAP and network ingress). See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide. |
IPv4-IPv6 128 bit Resource |
Resources allocated toward ingress ACLs using IPv4 or IPv6 (with 128-bit IP addresses) classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide. |
IPv6 64 bit Resource |
Resources allocated toward ingress ACLs using IPv4 or IPv6 (with 64-bit IP addresses) classification. See the 7210 SAS-Mxp, R6, R12, S, Sx, T Router Configuration Guide. |
Eth CFM |
Resources allocated toward Ethernet CFM (UP MEP, Down MEP, MIPs, and so on) |
down-mep |
Resources allocated toward ETH-CFM Down MEP |
Sap Egress QoS resource |
Resources allocated toward SAP Egress queues |
Egress Internal CAM |
Resources allocated toward egress internal tcam pool |
Sap Egress ACL resource |
Resources allocated for egress ACLs (SAP and IP interface) |
MAC and IPv4 Resource |
Resources allocated toward egress ACLs with IPv4 or MAC criteria |
Mac-only Resource |
Resources allocated toward egress ACLs with MAC criteria |
IPv6 128 bit Resource |
Resources allocated toward egress ACLs with IPv6 (with 128-bit IP addresses) criteria |
MAC and IPv6 64 bit Resource |
Resources allocated toward egress ACLs with IPv6 (with 64-bit IP addresses) criteria or MAC criteria |
A:NS1653C0258# show card "A" fabric-port-status
===============================================================================
Fabric Connectivity Information
===============================================================================
Slot No Equipped Type Fabric Port State
-------------------------------------------------------------------------------
1 imm-sas-b-16tx up
2 imm-sas-b-11csfp up
3 imm-sas-b-11csfp up
4 imm-sas-b-16tx up
5 imm-sas-b-16tx up
6 imm-sas-b-4sfp+ up
7 imm-sas-b-2sfp+ up
8 imm-sas-b-10sfp-1sfp+ up
9 imm-sas-b-10sfp-1sfp+ up
10 imm-sas-b-2sfp+ up
11 imm-sas-b-11csfp up
12 imm-sas-b-10sfp-1sfp+ up
A cpm-sf-sas-R12 up
B cpm-sf-sas-R12 up
-------------------------------------------------------------------------------
Entries found: 14
===============================================================================
A:NS1653C0258# show card "B" fabric-port-status
===============================================================================
Fabric Connectivity Information
===============================================================================
Slot No Equipped Type Fabric Port State
-------------------------------------------------------------------------------
1 imm-sas-b-16tx up
2 imm-sas-b-11csfp up
3 imm-sas-b-11csfp up
4 imm-sas-b-16tx up
5 imm-sas-b-16tx up
6 imm-sas-b-4sfp+ up
7 imm-sas-b-2sfp+ up
8 imm-sas-b-10sfp-1sfp+ up
9 imm-sas-b-10sfp-1sfp+ up
10 imm-sas-b-2sfp+ up
11 imm-sas-b-11csfp up
12 imm-sas-b-10sfp-1sfp+ up
A cpm-sf-sas-R12 up
B cpm-sf-sas-R12 up
-------------------------------------------------------------------------------
Entries found: 14
===============================================================================
Label |
Description |
---|---|
Slot No |
Displays the slot number of the card in the chassis |
Equipped Type |
Displays the card type that is actually populated in the slot |
Fabric Port State |
Displays the state of the fabric port: up or down |
mda [slot [/mda]] [detail]
show
Supported on all 7210 SAS platforms as described in this document.
This command displays MDA information.
a summary output of all MDAs is displayed in table format
Specifies the slot number for which to display MDA information.
Specifies the MDA number in the slot for which to display MDA information.
Displays detailed MDA information.
The following output is an example of MDA information, and Table: Output Fields: MDA Detailed and Table: Output Fields: MDA describe the output fields.
Sample output —7210 SAS-TA:SAST>show# mda detail
===============================================================================
MDA 1/1 detail
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 1 m12-sfp+10-tx+4-xfp up up
MDA Specific Data
Maximum port count : 26
Number of ports equipped : 26
Network ingress queue policy : default
Capabilities : Ethernet
Hardware Data
Platform type : N/A
Part number : 3HE08117AAAA01
CLEI code :
Serial number : NS1310C2059
Manufacture date : 03252013
Manufacturing string : (Not Specified)
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 41C
Temperature threshold : 68C
Low Temperature threshold : -20C
Software version : N/A
Time of last boot : 2015/02/16 08:20:58
Current alarm state : alarm cleared
Base MAC address : 4c:5f:d2:7c:fa:30
Firmware version : N/A
===============================================================================
A:SAST>show#
Label |
Description |
---|---|
Slot |
The chassis slot number |
Slot |
The MDA slot number |
Provisioned Provisioned-type |
The provisioned MDA type |
Equipped Mda-type |
The MDA type that is physically inserted into this slot in this chassis |
Admin State |
Up — The MDA is administratively up |
Down — The MDA is administratively down |
|
Operational State |
Up — The MDA is operationally up |
Down — The MDA is operationally down |
|
Maximum port count |
The maximum number of ports that can be equipped on the MDA card |
Number of ports equipped |
The number of ports that are actually equipped on the MDA |
Transmit timing selected |
Indicates the source for the timing used by the MDA |
Sync interface timing status |
Indicates whether the MDA has qualified one of the timing signals from the CPMs |
Transmit timing selected |
The transmit timing method which is presently selected and being used by this MDA |
Sync Interface timing status |
Indicates the status of the synchronous equipment timing subsystem |
Network Ingress Queue Policy |
Specifies the network queue policy applied to the MDA to define the queuing structure for this object |
Capabilities |
Specifies the minimum size of the port that can exist on the MDA. |
Part number |
The hardware part number. |
CLEI code |
The code used to identify the MDA. |
Serial number |
The MDA part number Not user modifiable |
Manufacture date |
The MDA manufacture date Not user modifiable |
Manufacturing string |
Factory-inputted manufacturing text string Not user modifiable |
Administrative state |
Up — The MDA is administratively up. |
Down — The MDA is administratively down. |
|
Operational state |
Up — The MDA is operationally up. |
Down — The MDA is operationally down. |
|
Time of last boot |
The date and time the most recent boot occurred. |
Current alarm state |
Displays the alarm conditions for the specific MDA. |
Base MAC address |
The base chassis Ethernet MAC address. Special purpose MAC addresses used by the system software are constructed as offsets from this base address. |
*7210SAS>show# mda detail
===============================================================================
MDA 1/1 detail
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 1 s48-t4-sfpp up up
MDA Specific Data
Maximum port count : 52
Number of ports equipped : 52
Network ingress queue policy : default
Capabilities : Ethernet
Fail On Error : Disabled
Egress XPL error threshold : 1000
Egress XPL error window : 60
Ingress XPL error threshold : 1000
Ingress XPL error window : 60
Hardware Data
Platform type : N/A
Part number : 1160400046
CLEI code :
Serial number : 01160400046
Manufacture date :
Manufacturing deviations : (Not Specified)
Manufacturing assembly number : 82-0827-01
Administrative state : up
Operational state : up
Temperature : 59C
Temperature threshold : 96C
Software version : N/A
Time of last boot : 2000/01/19 08:59:27
Current alarm state : alarm cleared
Base MAC address : a4:7b:2c:c6:69:d5
Firmware version : N/A
===============================================================================
*A:hw_sass_duth>show#
Sample output — 7210 SAS-Sx 10/100GE
*A:NS1633T0067>show# mda
===============================================================================
MDA Summary
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 1 s64-sfpp+4-cfp up up
===============================================================================
*A:NS1633T0067>show#
*A:NS1633T0067>show# mda detail
===============================================================================
MDA 1/1 detail
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 1 s64-sfpp+4-cfp up up
MDA Specific Data
Maximum port count : 68
Number of ports equipped : 68
Network ingress queue policy : default
Capabilities : Ethernet
Fail On Error : Disabled
Egress XPL error threshold : 1000
Egress XPL error window : 60
Hardware Data
Platform type : N/A
Part number : AABBCCDD-11
CLEI code :
Serial number : NS1633T0067
Manufacture date :
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Administrative state : up
Operational state : up
Temperature : 29C
Temperature threshold : 85C
Software boot (rom) version : (Not Specified)
Software version : (Not Specified)
Time of last boot : 2000/01/01 00:33:20
Current alarm state : alarm cleared
Base MAC address : d0:99:d5:8f:5e:43
Firmware version : N/A
===============================================================================
*A:NS1633T0067>show#
Label |
Description |
---|---|
Slot |
The chassis slot number |
MDA |
The MDA slot number |
Provisioned MDA-type |
The MDA type provisioned |
Equipped MDA-type |
The MDA type actually installed |
Admin State |
Up — Administratively up |
Down — Administratively down |
|
Ops State |
Up — Operationally up |
Down — Operationally down |
A:dut-a>show# mda detail
===============================================================================
MDA 1/1 detail
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
1 1 imm-sas-10sfp+1xfp up up
MDA Specific Data
Maximum port count : 11
Number of ports equipped : 11
Network ingress queue policy : default
Capabilities : Ethernet
Hardware Data
Platform type : N/A
Part number : 3HE05029AA
CLEI code : Sim CLEI
Serial number : mda-1
Manufacture date : 01012003
Manufacturing string : Sim MfgString mda-1
Manufacturing deviations : Sim MfgDeviation mda-1
Manufacturing assembly number : 01-2345-67
Administrative state : up
Operational state : up
Temperature : -128C
Temperature threshold : 74C
Software version : N/A
Time of last boot : 2015/01/30 07:37:12
Current alarm state : alarm cleared
Base MAC address : 20:89:01:01:00:01
Firmware version : N/A
===============================================================================
MDA 2/1 detail
===============================================================================
Slot Mda Provisioned Type Admin Operational
Equipped Type (if different) State State
-------------------------------------------------------------------------------
2 1 imm-sas-10sfp+1xfp up up
MDA Specific Data
Maximum port count : 11
Number of ports equipped : 11
Network ingress queue policy : default
Capabilities : Ethernet
Hardware Data
Platform type : N/A
Part number : 3HE05029AA
CLEI code : Sim CLEI
Serial number : mda-1
Manufacture date : 01012003
Manufacturing string : Sim MfgString mda-1
Manufacturing deviations : Sim MfgDeviation mda-1
Manufacturing assembly number : 01-2345-67
Administrative state : up
Operational state : up
Temperature : -128C
Temperature threshold : 74C
Software version : N/A
Time of last boot : 2015/01/30 07:37:12
Current alarm state : alarm cleared
Base MAC address : 20:8a:02:01:00:01
Firmware version : N/A
===============================================================================
A:dut-a>show#
pools mda-id [/port] [access-app pool-name]
pools mda-id [/port] [network-app pool-name]
show
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the access-uplink operating mode
This command displays pool information.
Displays the pool information of the specified MDA.
Displays the pool information of the specified QoS policy.
Displays the pool information of the specified QoS policy.
The following output is an example of pool information, and Table: Output fields: pool describes the output fields.
Sample output — 7210 SAS-MxpA:Dut-A# show pools 1/1/1 network-egress
===============================================================================
Pool Information
===============================================================================
Port : 1/1/1
Application : System
MMU Configured CBS : 28728 KB
-------------------------------------------------------------------------------
ID FC-MAPS/ CBS (B) Depth A.CIR A.PIR
Queue MBS (B) O.CIR O.PIR
-------------------------------------------------------------------------------
Sap Egress Queues:
No Match Found
Network/Access Queues:
1/1/1 be 131328 0 0 1000000
262656 0 1000448
1/1/1 l2 131328 0 100000 1000000
262656 100032 1000448
1/1/1 af 131328 0 100000 1000000
262656 100032 1000448
1/1/1 l1 131328 0 100000 1000000
262656 100032 1000448
1/1/1 h2 131328 0 200000 1000000
262656 200064 1000448
1/1/1 ef 131328 0 200000 1000000
262656 200064 1000448
1/1/1 h1 131328 0 50000 1000000
262656 50016 1000448
1/1/1 nc 131328 0 50000 1000000
262656 50016 1000448
=======================================================================
Sample output — 7210 SAS-Mxp, 7210 SAS-R6 and
7210 SAS-R12
*A:7210SAS>show# pools 1/1/1 access-egress
===============================================================================
Pool Information
===============================================================================
Port : 1/1/1
Application : System
MMU Configured CBS : 20382 KB
-------------------------------------------------------------------------------
ID FC-MAPS/ CBS (B) Depth A.CIR A.PIR
Queue MBS (B) O.CIR O.PIR
-------------------------------------------------------------------------------
Sap Egress Queues:
No Match Found
Network/Access Queues:
1/1/1 be 131328 0 0 1000000
131328 0 1000448
1/1/1 l2 131328 0 100000 1000000
131328 100032 1000448
1/1/1 af 131328 0 100000 1000000
131328 100032 1000448
1/1/1 l1 131328 0 100000 1000000
131328 100032 1000448
1/1/1 h2 131328 0 200000 1000000
131328 200064 1000448
1/1/1 ef 131328 0 200000 1000000
131328 200064 1000448
1/1/1 h1 131328 0 50000 1000000
131328 50016 1000448
1/1/1 nc 131328 0 50000 1000000
131328 50016 1000448
===============================================================================
*A:7210SAS>show#
Label |
Description |
---|---|
Type |
Specifies the pool type |
ID |
Specifies the card/mda or card/MDA/port designation |
Application/Type |
Specifies the nature of usage the pool would be used for. The pools could be used for access or network traffic at either ingress or egress |
Pool Name |
Specifies the name of the pool being used |
Resv CBS |
Specifies the percentage of pool size reserved for CBS |
Utilization |
Specifies the type of the slope policy |
State |
The administrative status of the port |
Start-AvgThreshold |
Specifies the percentage of the buffer used after which the drop probability starts to rise above 0 |
Max-Avg |
Specifies the percentage of the buffer used after which the drop probability is 100 percent. This implies that all packets beyond this point will be dropped |
Time Avg Factor |
Specifies the time average factor the weighting between the previous shared buffer average utilization result and the new shared buffer utilization in determining the new shared buffer average utilization |
Actual ResvCBS |
Specifies the actual percentage of pool size reserved for CBS |
Admin ResvCBS |
Specifies the percentage of pool size reserved for CBS |
PoolSize |
Specifies the size in percentage of buffer space. The value '-1' implies that the pool size should be computed as per fair weighting between all other pools. |
Pool Total |
Displays the total pool size |
Pool Shared |
Displays the amount of the pool which is shared. |
Pool Resv |
Specifies the percentage of reserved pool size. |
Pool Total In Use |
Displays the total amount of the pool which is in use. |
Pool Shared In Use |
Displays the amount of the shared pools that is in use. |
MMU Configured CBS |
Displays the total amount of CBS buffers configured on the IMM across all the queues on the IMM. |