EVPN host mobility configuration

Figure 1 shows an example of a host connected to a source PE, PE1, that moved to the target, PE2. The figure shows the expected configuration on the VPRN interface, where R-VPLS 1 is attached (for both PE1 and PE2). PE1 and PE2 are configured with an ‟anycast gateway”, that is, a VRRP passive instance with the same backup MAC and IP in both PEs.

Figure 1. Host mobility within the same R-VPLS – initial phase

In this initial phase:

The configuration described in this section and the cases in the following sections are for IPv4 hosts, however, the functionality is also supported for IPv6 hosts. The IPv6 configuration requires equivalent commands, that use the prefix "nd-" instead of "arp-". The only exception is the flood-garp-and-unknown-req command, which does not have an equivalent command for ND.