This section applies also to FR interfaces on Sonet/SDH high-speed channels on ASAP MDAs. To
configure Frame Relay on the associated port/channel, the frame-relay
encapsulation type must be specified.
The following output shows a Frame Relay encapsulation type and the Frame Relay defaults.
A:ALA-7>config>port# info detail
----------------------------------------------
description "OC-3/OC-12 SONET/SDH"
access
ingress
pool default
resv-cbs default
slope-policy "default"
exit
exit
egress
pool default
resv-cbs sum
slope-policy "default"
exit
exit
exit
network
egress
pool default
resv-cbs default
slope-policy "default"
exit
exit
exit
sonet-sdh
framing sonet
clock-source node-timed
no loopback
speed oc12
report-alarm loc lrdi lb2er-sf slof slos
no report-alarm lais ss1f lb2er-sd lrei
threshold ber-sd rate 6
threshold ber-sf rate 3
section-trace byte 0x1
path
description "OC-3/OC-12 SONET/SDH"
mode access
encap-type frame-relay
no mtu
no mac
crc 32
no scramble
trace-string "Nokia 7750 ALA-"
report-alarm plop pplm puneq
no report-alarm pais prdi prei
signal-label 0xcf
frame-relay
lmi-type itu
mode dte
n393dce 4
n393dte 4
n391dte 6
n392dce 3
n392dte 3
t391dte 10
t392dce 15
exit
no shutdown
exit
exit
no shutdown
----------------------------------------------
A:ALA-7>config>port# pwc