Table: Actions for the bidirectional protection switching process describes the steps that a bidirectional protection switching process goes through during a typical automatic switchover.
| Status | APS commands sent in K1 and K2 bytes on protection line | Action | ||
|---|---|---|---|---|
| B -> A | A -> B | At site B | At site A | |
No failure (Protection line is not in use).  | 
No request  | 
No request  | 
No action  | 
No action  | 
Working line Degraded in direction A->B.  | 
SD on working channel 1  | 
No request  | 
Failure detected, notify A and switch to protection line  | 
No action  | 
Site A receives SD failure condition.  | 
Same  | 
Reverse request  | 
No action  | 
Remote failure detected, acknowledge and switch to protection line  | 
Site B receives Reverse request.  | 
Same  | 
Same  | 
No action  | 
No action  |